Page 1
Instructions for ThermoQ Metal Bath Hangzhou Bioer Technology Co., Ltd.
Page 2
All rights reserved. The Bioer Co. reserves the right to modify this Caution: manual at any time without notice. All rights reserved. Without prior written consent from Hangzhou Bioer Technology Co., Ltd., any part of the manual shall not be duplicated, reproduced or translated into any other language.
Page 3
IP20; Caution: Hangzhou Bioer Technology Co., Ltd. shall be irresponsible for the consequence resulted from user’s failure to observe the following requirements. a) Adapter The instrument is supplied by 24VDC DC adapter. Every instrument is equipped with adapter when leaving factory.
Page 4
Products for warranty maintenance shall be sent to the maintenance department designated by Hangzhou Bioer Technology Co., Ltd. by the user. The transportation fee incurred thereof shall be borne by the user. Hangzhou Bioer Technology Co., Ltd. will bear the transportation fee incurred by returning the instrument.
Page 5
After unpacking, the packing box and packing materials shall be well kept for future repair. For the damage of instrument occurring during transporting to the repair department due to improper package, Hangzhou Bioer Technology Co., Ltd. shall bear no liability.
Instructions for ThermoQ Metal Bath Contents Contents Chapter I Introduction -------------------------------------------------------------------------------------------- 1 Chapter II Features ------------------------------------------------------------------------------------------------ 2 1. N ......................2 ORMAL ORKING ONDITIONS 2. T ................... 2 RANSPORTATION TORAGE ONDITIONS 3. P ............................3 ERFORMANCE Chapter Iii Operation Guidance--------------------------------------------------------------------------------- 4 1.
Instructions for ThermoQ Metal Bath Chapter I Introduction Chapter I Introduction The product is metal bath adopting advanced microcomputer control, which can be widely applied to sample reservation, enzyme reservation and reaction, electrophoresis pre-degeneration and serum coagulation, etc.. The characteristics of the product are as follows: Small volume, light weight;...
Instructions for ThermoQ Metal Bath Chapter II Features Chapter II Features This chapter introduces the usage, transportation, storage conditions of the instrument, as well as its basic parameters, performance and functions. 1. Normal Working Conditions Ambient temperature: 10°C ∼ 30°C Relative humidity: ≤70%...
Instructions for ThermoQ Metal Bath Chapter II Operation Guidance Chapter III Operation Guidance This chapter mainly introduces structure of the instrument, keyboard and functions of all buttons and preparation before startup. When using the instrument for the first time, read the content in the chapter carefully before startup.
Instructions for ThermoQ Metal Bath Chapter II Operation Guidance 2.2 Installation of hot lid component 3. Display panel diagram Temperature adjustment button Temperature display window Temperature adjustment button Status indicator 4. Instructions for indicator lights and buttons 4.1 Instructions for indicator lights The white light is model status indicator light, when the indicator light is red, it shows the instrument is heating;...
Instructions for ThermoQ Metal Bath Chapter II Operation Guidance When the setting key is pressed, the instrument will switch to single-point operation no Caution matter it is under single-point operation or multi-point operation. Temperature could be set with the setting key and the time is ∞. Upon completion of setting, do not conduct any operation to the equipment, wait for 3~5s, the instrument will exit setting status...
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer Chapter IV Connect with Computer 1. System Configuration System environment Operation system: Windows XP/Windows VISTA/Windows7 Running environment: .Net Framework 2.0 Other software: PDF reader Lowest configuration: Processor: Pentium(R)4 Internal storage: 1GBs Hard disc: 10GB 2.
Page 14
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer c. Choose installation position of software, click “next ”. d. Choose installation folder, click “next”. — —...
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer e. Prepare to install, click “install”. Complete installation, click “Finish”. 3. Online Setup 3.1 Installation of USB Drive USB drive program must be installed before online. Click the accompanying disc “CP210x.exe”, install USB drive program.
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer 4. Software Operation Software includes user management, file management, equipment management, running file and other operation. The above diagram is software operation interface 1. Menu bar 2. Contents of instrument 3. Area for displaying and editing files 4.
Page 17
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer “create user” with right button. User name cannot be blank; The maximum length of user name is 12 bytes; User name could only include figures and letters (Under half-angle model); The same user name cannot be used in the same instrument.
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer e. Export user Click “export” , choose the folder to save the users, click “OK” to export user. If there is the same user name, the system will prop up whether to override it or not when exporting it.
Page 19
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer b. Edit and save Choose the files to be edited, click “edit” , or choose the option of “edit file” with right button. After editing, click “save” in menu bar Maximum sections: 9 Maximum recycling number: 99 Time scope: 1min~99h59min...
Page 20
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer d. Delete file Choose the file to be deleted from the list of equipment, click “delete” If the file is being edited, it cannot be deleted; e. Copy Choose the file to be copied, click “copy”...
Page 21
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer h. Export file Click “export” , choose the folder of user from the window popping up, click “OK” to export file. If there is file with the same user name, the system will prop up whether to override it or not when exporting it.
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer 4.3 Equipment Management Include connection operation (connect and disconnect) and instrument management (search instrument, add instrument, edit instrument, remove instrument and display all instruments). a. Connect Choose sub-item of equipment name in equipment list, click “connect or the option of “instrument connection”...
Page 23
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer d. Add instrument Click “add instrument” , the dialog box as shown on the right will appear. Input instrument name and instrument address, click to add instrument. Instrument name cannot be blank and the maximum byte is 12;...
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer When the instrument is being connected, instrument address cannot be edited. f. Remove instrument Choose sub-item of equipment name in equipment list, click “remove instrument” When the instrument is being connected, the instrument cannot be removed.
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer 4.5 Run a. Run local file If the instrument is running, after being connected with a computer, the instrument will continue to run. Running file is a local program of the instrument.
Page 26
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer Click the “real-time temperature” , on upper right corner of the running status diagram, it could display the real-time curve. C. System setup Click “system setup” , display system setup window, the status of hot lid and alarm sound (key click sound, running and completing alarm and fault alarm) can be set.
Page 27
Instructions for ThermoQ Metal Bath Chapter IV Connect Computer d. Check running history Click “run log” , the form of running history will pop up. e. Export experimental results After the finishing of file running, click to run “export experimental results”...
Instructions for ThermoQ Metal Bath Chapter V Failure Analysis and Troubleshooting Chapter V Failure Analysis and Troubleshooting This chapter mainly introduces possible failures of this instrument and reason analysis as well troubleshooting Failure Analysis and Troubleshooting Failure Cause Analysis Troubleshooting The first time:Please tune off power,then tune on it.
Page 32
H a n g z h o u B i o e r Te c h n o l o g y Co . , L t d . Add: No. 1192, Bin’an Road, Gaoxin (Binjiang District), Hangzhou P.C.: 310053 Tel: (0571) 87774252, 87774307, After-sales Service (Tel): 87774558 Fax: (0571)87774553, After-sales Service (Fax): 87774559 E-mail: instrument@bioer.com.cn Hot line for free customer service: 800-857-1279 www.bioer.com.cn...
Need help?
Do you have a question about the ThermoQ and is the answer not in the manual?
Questions and answers