Table 2-15 T1 Led Indications; Figure 2-81 1Priu-C1 Led Indication Pattern Of Layer 1 On T1 Unit - NEC SL1000 Hardware Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
T1 Alarm Mode
Refer to following figure for LED pattern information. LED indications for the T1 are listed in following
table.
120 ms
red
LOS
green
red
AIS
green
red
OOF
green
red
RAI
green

Figure 2-81 1PRIU-C1 LED Indication Pattern of Layer 1 on T1 Unit

Alarm
LOS
LOS (Loss of Signal (Red Alarm))
No Signal (Analog Interface)
AIS
AIS (Alarm Indication Signal (Blue
Alarm))
OOF
OOF (Out of Frame (Red Alarm))
RAI
RAI (Remote Alarm Indication (Yellow
Alarm))
No alarm
System does LED control
Hardware Manual
1 cycle 3.8 sec (120ms x 32=3840 ms)

Table 2-15 T1 LED Indications

Details of the alarm
The LED indication pattern
Following an alarm blink (red, green, red, green), a red
LED lighting up.
Following an alarm blink (red, green, red, green), a red
LED flashes on and off slowly twice
Following an alarm blink (red, green, red, green), a red
LED and a green LED flash on and off 3 times simultane-
ously.
Following an alarm blink (red, green, red, green), a green
LED flashes on and off twice.