The Transition Networks CPSMC0100-210 single-slot PointSystem™ chassis is
equipped with an internal power supply, and is designed for installation of a single,
selectable Transition Networks PointSystem™ slide-in-module media converter
with a maximum of 12 Watts.
Part Number
Description
CPSMC0100-210
Single-slot PointSystem™ chassis, with an internal power
supply, intended for installation of any PointSystem™ slide-
in-module media converter up to 12 Watts.
Note: The following media converter families are not compatible with Transition
Networks CPSMC0100-210 single-slot PointSystem™ chassis: C4TEF,
CAPTF, CBFTF-120, CBFTF-140, CEMTF, CGFEG and the CMEFG.
User's Guide
CPSMC0100-210
Single-Slot PointSystem™ Chassis
with Internal Power Supply
Installation . . . . . . . . . . . . . . . . . .2
Technical Specifications . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . .7
Compliance Information . . . . . . . .8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPSMC0100-210 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Transition Networks CPSMC0100-210

  • Page 1 CPSMC0100-210 Single-Slot PointSystem™ Chassis with Internal Power Supply The Transition Networks CPSMC0100-210 single-slot PointSystem™ chassis is equipped with an internal power supply, and is designed for installation of a single, selectable Transition Networks PointSystem™ slide-in-module media converter with a maximum of 12 Watts.
  • Page 2: Installation

    Note: The maximum power capacity for the chassis slot is 12 Watts. Note: The CPSMC0100-210 chassis is rated as “Class B” only when Class B compliant slide-in-module media converters are installed. The chassis will drop to a “Class A“...
  • Page 3: Technical Specifications

    Installation -- Continued Grounding the Media Converter The CPSMC0100-210 single-slot chassis comes equipped with grounding lugs located on the back panel. They require a grounding conductor wire terminated with a two-hole, compression-type, grounding connector. The grounding wire -- which must be a copper conductor -- is not included with the chassis and must be provided by the customer/installer.
  • Page 4: Troubleshooting

    CPSMC0100-210 Regulation: EMC Directive 89/336/EEC Purpose: To declare that the CPSMC0100-210 to which this declaration refers is in conformity with the following standards: EN 55022:1994+A1:1995+A2:1998 Class A&B; EN 55024:1998+A1:2002; FCC Part 15 Subpart B; 21CFR subpart J; EN 61000-3-2:2001; Telcordia GR-1089-CORE sect. 3.2.2 I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
  • Page 5: Compliance Information

    Konformität. In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document.