Available languages

Available languages

Separate heating and cooling transformers
Single stage heat pump with auxiliary heat (electric or dual fuel)
Two stage heat pump with auxiliary heat (electric or dual fuel)
C
Common wire (optional)
W
Heat relay
G
Fan relay
Y
Compressor contactor (stage 1)
R
Power
Rc
Power
C
Common wire (optional)
AUX Auxiliary/Emergency heat
O/B
Reversing valve
G
Fan relay
Y
Compressor contactor (stage 1)
R
Power
C
Common wire (optional)
AUX Auxiliary/Emergency heat
O/B
Reversing valve
Y2
Compressor contactor (stage 2)
G
Fan relay
Y
Compressor contactor (stage 1)
R
Power
9
Notes
• Thermostat C wire
is optional for
this application.
C wire required if
Homekit is used.
• Set the R Jumper
Switch on the wall
plate to R & Rc
Notes
• Thermostat C wire
is optional for
this application.
C wire required if
Homekit is used.
• Set the R Jumper
Switch on the wall
plate to R
Notes
• Thermostat C wire
is optional for
this application.
C wire required if
Homekit is used.
• Set the R Jumper
Switch on the wall
plate to R