Chore-Time Chore-Tronics Manual

Load cell indicator
Hide thumbs Also See for Chore-Tronics:

Advertisement

Quick Links

Chore-Tronics
®
Load Cell Indicator
June 2008
MT2316A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Chore-Tronics and is the answer not in the manual?

Questions and answers

Summary of Contents for Chore-Time Chore-Tronics

  • Page 1 Chore-Tronics ® Load Cell Indicator June 2008 MT2316A...
  • Page 2: Conditions And Limitations

    CTB Inc. Warranty Load Cell Indicator CTB Inc. Warranty CTB Inc. warrants each new product manufactured by it to be free from defects in material or workmanship for one year from and after the date of initial installation by or for the original purchaser. If such a defect is found by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B.
  • Page 3: Introduction To The Control

    Load Cell Indicator Overview Overview The Chore-Tronics Load Cell Indicator is used to indicate the amount of weight in a maximum of two different feed bins that are setting on two different sets of loadcells. facility. Introduction to the Control...
  • Page 4: Navigation Buttons

    Introduction to the Control Load Cell Indicator Navigation Buttons These buttons allow you to scroll up and down in the screens that have more than 8 lines. Continuously pressing the up or down arrow button increases the scrolling speed. When you are in the Edit Mode the left and right arrow keys move the cursor to editable (changeable) positions.
  • Page 5: Using The Navigation Buttons

    Load Cell Indicator Introduction to the Control How to Maneuver in the Viewing Screen •The procedures below give a brief overview on the use of the Navigation Buttons and the Edit Buttons. •Screen 1, "Setup" is used for this example. Using the Navigation Buttons 1.
  • Page 6 Introduction to the Control Load Cell Indicator Using the Edit Buttons The Edit Mode is entered by pressing the Edit Button. Pressing the Edit Button a second time exits the Edit Mode. 1. Press BUTTON 3. The Setup screen appears (Figure 6). Control Number Clock Type 12 HR...
  • Page 7: Glossary Of Terms

    Load Cell Indicator Glossary of Terms Glossary of Terms Noticing an Alarm “Noticing” an alarm is a very important part of using the alarm system. With button presses, you can tell the Control that you have “seen” the alarm message. The simplest way to do this is to first press the alarm button to read the alarm message(s) at the top of the alarm screen.
  • Page 8 Screen 3: Setup Load Cell Indicator Screen 3: Setup Control Number Clock Type 12 HR Time 11:01p Date 25 Aug 06 Total Silo Bins CALIBRATE SILO BIN 1 Actual = 123456 Zero Weight = 123456 Y/N CALIBRATE SILO BIN 2 Actual = 123456 Zero Weight = 123456 Y/N...
  • Page 9: Initial Setup Procedure

    Load Cell Indicator Initial Setup Procedure Initial Setup Procedure Once the LCI has been properly installed, the LCI is ready to be setup. 1. Go to the Setup Screen (Screen 3) by pushing button 3. 2. Setup the LCI Control number, time, and date. Key in the LCI how many bins are connected totthe LCI. 3.
  • Page 10: Alarm History

    Control Operation Overview Load Cell Indicator Control Operation Overview In Screen 1 (Button 1) the weight of each Bin is displayed. The unit of measure displayed depends upon how the LCI was calibrated in the Setup Screen. Alarms At the top of screen 2 a current alarm condition(s) will be listed. If there are no alarm conditions, the status of the alarm system will show at the top of the screen.
  • Page 11: Control Installation

    SJB. See the wiring diagram on page 14 for information on connecting the SJB to the LCI. Service Alarms Listed below are additional alarm codes that relate to the internal operation of the LCI. Contact the nearest Chore-Time Distributor or CTB service personnel if one of these alarms occur. SYSTEM FAILURE 100 SYSTEM FAILURE 111...
  • Page 12: Wiring Diagram

    Wiring Diagram LCI CONTROL 120 OHM RESISTOR REQUIRED AT THE TO PC HOOK UP BEGINING AND END (MUST HAVE C CENTRAL) OF THE I/O NET SJB Control 24V EXT GND - I/O + FNET -24 VOLT +24 VOLT SUPPLY TO SUPPLY TO SJB (MAX 6 CELLS) SUPPLY VOLTAGE...
  • Page 13: Part Numbers

    Load Cell Indicator Part Numbers Part Numbers Item Description Part No. Plate, Model 4B Top 41327 4 x 20 Display 41318 Plain Control Box Lid 30859-1 Control Box 30860-3 Control Box Lid 30859-1 KD Board 41316 Grounding Rail 43384-2 Plate, Mod 4B, SP, NV Bottom 41328 Control Box Latch 30862 Box Latch Pivot...
  • Page 14: Revisions To This Manual

    Part Numbers Load Cell Indicator Note: The original, authoritative version of this manual is the [English] version produced by CTB, Inc. or any of its subsidiaries or divisions, (hereafter collectively referred to as "CTB"). Subsequent changes to any manual made by any third party have not been reviewed nor authenticated by CTB.