Hitachi SRW-0J Instruction Manual

Remote operator

Advertisement

HITACHI INVERTER
REMOTE OPERATOR
SRW-0J , SRW-0EX
I N S T R U C T I O N
M A N U A L
T h a n k y o u f o r p u r c h a s i n g R e m o t e O p e r a t o r . T h i s i n s t r u c t i o n m a n u a l i s w r i t t e n a b o u t
h o w t o u s e R e m o t e O p e r a t o r . C o u l d y o u u s e t h i s m a n u a l f o r i n s p e c t i o n , m a i n t e n a n c e ,
s e t t i n g a n d u s e i t w i t h t h e m a i n b o d y o f i n v e r t e r . A f t e r r e a d i n g t h i s m a n u a l , k e e p i t a t
h a n d f o r f u t u r e r e f e r e n c e .
HITACHI
N B 6 1 5 X

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi SRW-0J

  • Page 1 HITACHI INVERTER REMOTE OPERATOR SRW-0J , SRW-0EX I N S T R U C T I O N M A N U A L T h a n k y o u f o r p u r c h a s i n g R e m o t e O p e r a t o r . T h i s i n s t r u c t i o n m a n u a l i s w r i t t e n a b o u t h o w t o u s e R e m o t e O p e r a t o r .
  • Page 2 SAFETY To get best performance with Remote Operator, read this manual and all of the warning sign attached to the inverter carefully before installation and operation, and follow the instructions exactly. Keep this manual handy for your quick reference. Definitions and Symbols A safety instruction (message) is given with a hazard alert symbol and a signal word;...
  • Page 3 Revision History Table The Date Operation Revision Contents of Issue Manual No. Initial Release of Manual NB615X Apr. 2000 NB615X...
  • Page 4 SAFETY PRECAUTIONS WARNING Never modify the unit. Otherwise, there is a danger of electric shock and/or injury. CAUTION Avoid locations of high temperatures, high humidity, dew condensation, dust, corrosive gases, explosive gases, combustible gases, coolant mist and sea damage etc. Install indoors, to avoid direct sunlight and the unit should be well ventilated.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS Chapter 1 Introduction .……………………………………………… Chapter 2 Notes handling ………………………………………… Chapter 3 Connection, wiring, attaching ……………………… Chapter 4 Name of parts and contents ………………………… Chapter 5 Copy function and operation …………………………… Chapter 6 Setting operating mode ………………………………… Chapter 7 Error message ……………………………………………...
  • Page 6: Chapter 1 Introduction

    (injury,falling or dents in the body) during transpotation of the unit. Content of package 1. Main body of remote operator :1 2. Instruction manual If you have any questions please contact your supplier or the local Hitachi Distributor with the following information.
  • Page 7 1.4 Question and Warranty of the unit 1.4.1 Request upon asking ・ If you have any questions regarding damage to the unit, unknown parts or for general enquiries, please contact your supplier or the local Hitachi Distributor with following information. (1) Model (2) Product Model Code...
  • Page 8: Chapter 2 Notes Of Handling

    Chapter 2 Notes of handling Handling the Cable (Optional) 1. Avoid pulling the cable forcibly for operation or moving the operator by its cable. 2. Fix the cable when the operator is housed in the object inverter panel. 3. Separate the cable more than 15cm from the main circuit, the main circuit relay, and the circuit control cable.
  • Page 9: Connection, Wiring, And Attaching

    Chapter 3 Connection, wiring, and attaching Connect to inverter 3.1.1 Connecting to operator on the surface of cover (SJ300/L300P series only ) 1. After setting up like a following figure, insert the operator to the connector vertically. 2. Turn on the power supply of the inverter , and Confirm that LCD screen of the operator is 3.1.2 Connecting by cable (Option) 1.
  • Page 10: Name Of Parts And Contents

    Chapter 4 Name of parts and contents SRW-0J SRW-0EX lamp ALARM HITACHI HITACHI R lamp POWE POWER POWER ALARM PRG ALARM LCD monitor RUN la PROGR AM lamp 0060.00Hz 0060.00Hz Iout 0022.5A Iout 0022.5A READ k REMOTE lamp COPY k...
  • Page 11: Chapter 5 Copy Function And Operation

    Chapter 5 Copy function and operation Copy Function 1. The copy function can be used only while the inverter stops. While the inverter is running, tripping, reset or soft-locked, the function is invalidated. Press the Read key or copy key. The following display will appear corresponding to the entered key.
  • Page 12 Chapter 5 Copy function and operation Read Lock Operation More than 2 second, press the ― ― STOP/RESET keys at the same time on general operation. [Read Lock.] READ LOCK …… “READ” function is invalidity LANGUAGE ENGLISH If you press the key, data wil be stored.
  • Page 13: Chapter 6 Setting Operating Mode

    2400 4800 Comunicatin 2400 speed(bps) 9600 (NOTE 1) 19200 Select “EXECUTE “ ,and initialized ; Whether set de- SRW-0J: fault or not SET DEFAULT BPS : 4800 CANCEL CANCEL LANGUAGE SELECT : OFF (NOTE 1) EXECUTE OPERATOR TYPE :SRW SRW-0EX:...
  • Page 14: Chapter 7 Error Message

    Chapter 7 Error message Error messages to be displayed on the screen are classified into inverter errors and op- erator errors. They will appear on the screen as shown below. Inverter error message ERR1 ******** For more information, refer to the inverter instruction manual.
  • Page 15: Chapter 8 Trouble Shooting

    Chapter 7 Error message The data written in If the same error recurs inverter when copying is done COPY ROM matches with again, the inverter is data in the remote defective.(NOTE 2) operator. (NOTE 1) Except SJ300/L300P/SJ100/L100 series. (NOTE 2) Refer to the each inverter instruction manual.
  • Page 16: Chapter 9 Specification

    Chapter 8 Trouble shooting For the troubleshooting of the inverter, refer to the inverter instruction manual. In this section, the troubleshooting of the operator will be described. 1. No data appears on the screen. The inverter power Turn ON the inverter supply is ON.
  • Page 17: For Sj300/L300P Series

    Chapter 10 LCD display and operating for SJ300/L300P series 10.1 Type of LCD screen, configuration LCD LCD screens are classified five types. Each of mode’s operation way is written on 10.3 (display monitor screen display in top row and 1. Monitor mode A function mode simple display in bottom row.) Monitor Item 1 0060.00H...
  • Page 18 Chapter 10 LCD display and operating for SJ300/L300P series 10.2 The way of changing mode Each of the way of changing is written following figure. Monitor mode A Function mode 0060.00Hz >F001 SET-Freq. >A001 000.00Hz Monitor mode B 0060.00Hz Iout 0022.5A Trip monitor ~...
  • Page 19 Chapter 10 LCD display and operating for SJ300/L300P series Monitor Mode A 0000.00Hz >F001 0010.00Hz Press the key several times, then select "Iout"(Output current monitor) Iout 0000.0A >F001 0010.00Hz Press the key, then move the cursor down. Iout 0000.0A >F001 0010.00Hz Press the key several times, then select "A001"(Method of frequency command selection).
  • Page 20 Chapter 10 LCD display and operating for SJ300/L300P series ・Example 2 When changing from A001 to C021. Monitor Mode A Iout 000.0A >A001 Press the key, then move the cursor to the bottom row. Iout 0000.0A >A001 Press the key, then move the cursor to the code number display "A". Iout 0000.0A >A001...
  • Page 21 Chapter 10 LCD display and operating for SJ300/L300P series (2) Monitor Mode B key and key select the monitor item which you desired, press the store key. ・ Example In case of selecting output current monitor in monitor item 2 and electric power monitor in monitor item 3.
  • Page 22 Chapter 10 LCD display and operating for SJ300/L300P series (3)Trip Monitor How to display each of trip data is following explanation. ・Example In case of display last time (ERR2) trip contents. Trip Monitor ERR1 OC. Accel F 0037.00Hz ACC Press the key to select "ERR2".
  • Page 23 Chapter 10 LCD display and operating for SJ300/L300P series Trip history trip data of ERR2 in the display examples are arranged following list. Item Data value Factor of tripping Over . V ( Overload voltage trip ) Inverter status on tripping DEC (...
  • Page 24 Chapter 10 LCD display and operating for SJ300/L300P series 2. Method of transferring to other function. ・Example Display A002(Operation setting selection), then change from remote to terminal.
  • Page 25 Chapter 10 LCD display and operating for SJ300/L300P series Function mode >F001 SET-Freq. 0000.00Hz Press the key, then move the cursor to the display code number "F". >F001 SET-Freq. 0000.00Hz Press the key, then change the display code number "F" to "A". >...
  • Page 26 Chapter 10 LCD display and operating for SJ300/L300P series ・ Example In case of changing from 0% to 10%, in display A054(DC braking power on stop). Function mode >F001 SET-Freq. 0000.00Hz Press the key 5 times to move the cursor to the group display section. >F001 SET-Freq.
  • Page 27 Chapter 10 LCD display and operating for SJ300/L300P series (5)User display User-display-mode display the item to be selected by U001 ~ U012. Press the ― keys more than 2 seconds and press them at the same time on general operation. The item is >A001 Name of group...
  • Page 28 Chapter 10 LCD display and operating for SJ300/L300P series 0000.00Hz Multi-speed 1 | 0000.00Hz Multi-speed 15 0000.00Hz Frequency from option 1 0000.00Hz Frequency from option 2 RS485 0000.00Hz Frequency from RS485 Output frequency 0000.00Hz 0.00 - 400.00 (Hz) monitor Output current Iout 0000.0A 0.0 - 999.9 (A) monitor...
  • Page 29 Chapter 10 LCD display and operating for SJ300/L300P series (2) Trip monitor mode Display contents Function name Remark (Example) E R R 1 O C . A c c e l Trip monitor 1 1-(1) 0035.23Hz ACC (Frequency) E R R 1 O C .
  • Page 30 Chapter 10 LCD display and operating for SJ300/L300P series (3) Function mode (F mode) Function name Display contents Display contents >F001 SET-Freq. 0.00 , Starting frequency-Max. frequency Hz Output frequency 0000.00Hz >F001 SET-Freq. 0.00 , Starting frequency-2 Max frequency Hz 2FS 0000.00Hz >F001 SET-Freq.
  • Page 31 Chapter 10 LCD display and operating for SJ300/L300P series (4) Function mode (1/15) Function name Display Data range Frequency setting >A001 F-SET TRM(terminal)/REM(operator)/RS485(RS485 selection SELECT )/OP1(option 1)/OP2(option 2) Operation setting >A002 TRM(terminal)/REM(operator)/RS485(RS485 selection SELECT )/OP1(option 1)/OP2(option 2) >A003 F-BASE Base frequency 30.
  • Page 32 Chapter 10 LCD display and operating for SJ300/L300P series , >A024 SPEED 0.00 Starting frequency-maximum Multi-speed 4 04S 0000.00Hz frequency(Hz) (NOTE 1) SJ300 series only . (2/15) Function name Display Data range , >A025 SPEED 0.00 Starting frequency-maximum Multi-speed 5 05S 0000.00Hz frequency(Hz) ,...
  • Page 33 Chapter 10 LCD display and operating for SJ300/L300P series Manual Torque 0.0 - 20.0 % >A342 3V-Boost boost Code 01.0% (NOTE 1 ) motor Manual Torque >A043 V-Boost 0.0 - 50.0 % boost 05.0% point Manual Torque >A243 2V-Boost 0.0 - 50.0 % boost 05.0% point, 2...
  • Page 34 Chapter 10 LCD display and operating for SJ300/L300P series >A065 JUMP Jump frequency2 0.00 - 400.00 Hz 0000.00Hz Jump frequency >A066 JUMP 0.00 - 10.00 Hz width 2 00.50Hz >A067 JUMP Jump frequency3 0.00 - 400.00 Hz 0000.00Hz Jump frequency >A068 JUMP 0.00 - 10.00 Hz...
  • Page 35 Chapter 10 LCD display and operating for SJ300/L300P series stage adjustable >A294 2ACCEL TM(change with 2CH terminal) / selection (2 motor) CHANGE FREE(change with setting) acceleration >A095 ACCEL 0.00 - 400.00 Hz frequency CHFr 0000.00Hz acceleration >A295 2ACCEL 0.00 - 400.00 Hz frequency(2 CHFr 0000.00Hz motor)
  • Page 36 Chapter 10 LCD display and operating for SJ300/L300P series Instantaneous power >b005 failure/under-voltag 16(16 times) / FREE(free) RETRY retry time selection Open-phase >b006 PH-FAIL OFF(invalid) / ON(valid) selection SELECT Frequency setting to >b007 0.00 – 400.00 Hz match 0000.00Hz Electronic thermal >b012 E-THM 0.2*constant current-1.20*constant current(A)
  • Page 37 Chapter 10 LCD display and operating for SJ300/L300P series Overload restriction >b025 OLOAD 0.5* rated current-2.00* rated current(A) level 2 2LEVEL 0000.0A (NOTE 2) Overload restriction >b026 OLOAD 0.10 - 30.00(s) limit constant 2 2CONST 01.00 MD0(impossible to change the data except this item when SFT terminal is ON) / MD1(impossible to change the data except setting frequency item when SFT terminal is...
  • Page 38 Chapter 10 LCD display and operating for SJ300/L300P series Start voltage of non- >b051 IPS-DECEL 0.0 - 999.9(V) stop function setting 0000.0Vdc (NOTE 1) OV LAD-STOP level >b052 IPS-DECEL 0.0 - 999.9(V) of non-stop function 0000.0Vdc (NOTE 1) setting Deceleration time of 0.01- 3600.00(s) >b053 IPS-DECEL non-stop function...
  • Page 39 Chapter 10 LCD display and operating for SJ300/L300P series >b101 FREE_V/F 165 Free V/F voltage 1 0 - 800.0(V) 000.0V Free V/F frequency >b102 FREE_V/F 0 - Free V/F frequency3(Hz) 0000Hz >b103 FREE_V/F 167 Free V/F voltage 2 0 - 800.0(V) 000.0V Free V/F frequency >b104 FREE_V/F...
  • Page 40 Chapter 10 LCD display and operating for SJ300/L300P series Intelligent input 6 >C006 IN-TM SET3(3 control) / RS(Reset inverter) / setting (NOTE 1) STA(3wire run) / STP(3wire keep) / F/R(3wire Intelligent input 7 >C007 IN-TM forward/reverse) / PiD(PiD selection valid setting (NOTE 1) invalid) / PIDC(PID integrating...
  • Page 41 Chapter 10 LCD display and operating for SJ300/L300P series NO : NO Input FW a/b >C019 IN-TM (NO/NC) selection O/C-FW NC : NC Intelligent output >C021 OUT-TM RUN(running) / FA1(Frequency arrival type1 11 setting signal) FA2(over setting frequency) OL(Overload advance notice signal) Intelligent output...
  • Page 42 Chapter 10 LCD display and operating for SJ300/L300P series (11/15) Function name Display Data range NO : NO Alarm relay output >C036 OUT-TM O/C-AL NC : NC Overload advance >CO40 ON(On accel. And decel,constant speed) / notice signal Mode CRT(Only constant speed) output mode Overload advance >C041...
  • Page 43 ZERO 00000 NOR(Invalid) / NRT(Valid (the motor does not >H001 Autotuning selection rotate))/AUT(Valid (the motor rotates)) AUTO (NOTE 1) NOR(Hitachi general purpose motor data) / motor constant >H002 AUT(Autotuning data) / ON-AUT(Autotuning selection DATA data with online autotuning) (NOTE 1)
  • Page 44 Chapter 10 LCD display and operating for SJ300/L300P series motor pole >H204 2AUX 2P,4P,6P,8P (pole) selection speed response >H005 0.001 - 65.535 setting 1.590 (NOTE 1) speed response >H205 2AUX 0.001 - 65.535 setting 1.590 (NOTE 1) (NOTE 1) SJ300 series only . (13/15) Function name Display...
  • Page 45 Chapter 10 LCD display and operating for SJ300/L300P series 0.000 - 999.9000( ㎏㎡ ) motor constant >H034 J(Autotuing data) 0000.00 (NOTE 1) 0.000 - 999.9000( ㎏㎡ ) motor constant >H234 2AUX J(Autotuing data) 0000.00 (NOTE 1) PI-control >H050 0.0 – 1000.0(%) propor- 0100.0% (NOTE 1)
  • Page 46 Chapter 10 LCD display and operating for SJ300/L300P series Orientation comple- >P017 FEEDBACK 0 – 10000 (pulse) tion range setting 00005pls (NOTE 1) Orientation comple- >P018 FEEDBACK 0.00 - 9.99(s) tion delay time 000.00s (NOTE 1) setting Electronic gear >P019 FEEDBACK FB(Feed back) / REF(Reference) position selection EGRP...
  • Page 47 Chapter 10 LCD display and operating for SJ300/L300P series >U011 USER 327 User11 selection no / d001-P032 (NOTE 2) __no >U012 USER 328 User12 selection no / d001-P032 (NOTE 2) __no (NOTE 1) SJ300 series only . (NOTE 2) L300P series : no / d001 – P031...
  • Page 48 Chapter 10 LCD display and operating for SJ300/L300P series 10.5 Diagnosis (1)Inverter error message Display of remote operator Name Description ERR1 *** At constant Motor is restricted and OC. Drive Speed decelerates rapidly, excessive On deceleration current is drawn through the OC.
  • Page 49 Chapter 10 LCD display and operating for SJ300/L300P series Display of remote operator Name Description ERR1 *** When an instantaneous power failure occurs for more than 15ms, the inverter output is switched off. Once the instantaneous power failure wait time has Temporary power loss elapsed and the power has not been restored it is Inst.
  • Page 50 Chapter 10 LCD display and operating for SJ300/L300P series (2) Inverter warning massages Warning display condition Remote operator (6 languages available) Maximum frequency setting < Frequency upper limit setting Fmax < Lim-H < Frequency lower limit setting Fmax < Lim-L <...
  • Page 51 Chapter 10 LCD display and operating for SJ300/L300P series > Multi-speed frequency setting(1-15) Fmin > SPEED > Jogging frequency setting Fmin > JG Jump frequency n +-Jump width n Multi-speed frequency setting(0) Fjp <> FS < (n=1,2,3) > Multi-speed frequency setting(0) Fjp <>...

This manual is also suitable for:

Srw-0ex

Table of Contents