Description And Appropriate Use - Schaudt Electrobloc EBL 208 S G Instruction Manual

Table of Contents

Advertisement

R
8110600 BA / EN
Instruction Manual Electrobloc EBL 208 S G
Only use original fuses rated as specified in the instruction manual.
Danger of burning! During operation the back of the Electrobloc gets
hot. Do not touch.
Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Electrob-
loc or an excessively high battery working temperature (more than
30 °C).
The AES refrigerator fuse may only be used if a AES refrigerator is con-
nected. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.
An incorrectly set battery selector switch damages the living area battery.
Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.
When the living area battery is separated from the Electrobloc by the bat-
tery cut-off switch, the frost protection valve of the heater system opens.
Before and after shutdown, the living area battery must be fully recharged
to avoid battery damage. For this purpose the vehicle must be connected
to mains supply for a minimum of 12 hours with an 80 Ah battery and
16 hours with a 160 Ah battery.
Do not operate the Schaudt solar charge regulator without a battery. This
might damage the solar charge regulator or any connected consumers. If
the battery is going to be changed or removed, please first take off the pos-
itive lead "+ Solar Module" on the solar charge regulator.
To avoid voltage peaks during warm-up, do not connect the generator until
it is running in a stable manner. Otherwise, the Electrobloc, 12 V consum-
ers or other connected equipment might get damaged. It is essential that
the generator complies with the mains supply specifications.
The mains supply on board car ferries might not always be perfect. There-
fore, never connect the Electrobloc to the mains on car ferries. Otherwise,
the Electrobloc, 12 V consumers or other connected equipment might get
damaged.
3

Description and appropriate use

The electrical management system Electrobloc EBL 208 S G consists of:
the LAS 1218 charger module
the 12 V distribution
fuses for the 12 V circuits
a battery monitor module
other control and monitoring functions
The charger module is a primary controlled switch-mode power supply. This
modern switching technology achieves high charging performance at a com-
pact size and low weight.
Edition: 20.11.2018
3

Advertisement

Table of Contents
loading

Table of Contents