2. MAJOR UNIT REPLACEMENT
Adjusting the print head position
1 Fit the jig in the platen and strip shaft.
2 Press the jig at an angle of 45 until it is sung against the print head. Then secure the print head.
Jig
3 Remove the jig.
4 Refer to page 6-43 and clear the maintenance counter.
5 Refer to page 6-31 and perform test print.
NOTE: Use caution to prevent damage to the element during adjustment of the print head.
Strip Shaft
Strip Shaft
Platen
2-9
(Revision Date Feb. 01, '96)
2.6 REPLACING THE PRINT HEAD
Platen
Print Head
Ceramic
Fig. 2-14