REPLACING THE FUSE
TO REPLACE THE FUSE ON THE POWER SUPPLY PCB:
1. Remove the power supply PCB unit .
(Refer to Disassembly.)
2. Replace the fuse.
CAUTION:
This symbol indicates the F1 fuse on the power supply PCB.
Replace with the same type T2AH, 250V fuse.
ATTENTION:
Ce symbole indique le F1 fusible se trouvant sur la carte de circuit electrique.
Ne remplacer ce fusible que par un fusible identique de T2AH, 250V.
SAFETY RELATED COMPONENT. USE ONLY EXACT REPLACEMENT PART AS SPECIFIED.