Single phase - 3.6-rohs/3.6/6/8/10/14/18/22
Hide thumbs Also See for 1600EP Series:
Table of Contents

Advertisement

Capacity
environment
operating temperature
(15 – 25° C recommended)
Storage temperature
installation area
operating humidity
altitude
acoustical noise
heat generation
operation Diagnosis
battery Check
input oV protection
battery lifetime
internal temperature
event Data Storage
applications
Switches
bypass Switch
bypass Disable
automatic retransfer
User interface
real time Clock
Schedule operation
rUn/Stop Disable
autostart
remote on/oFF
leD Display
lCD Screen
UpS operation: 6 Keys
buzzer Volume
power Connections
emergency power off
remote Contacts
rS232 aSCii interface
1.
Input/output figures rated for 240 volts. Output ratings given for 0.85PF are only valid when the input voltage is
greater than 204 volts; otherwise, ratings given for 0.70pF are applicable.
2.
at 6600 ft (2000 m) above sea level, output capacity should be derated by 3%
1600ep Series instruction manual
STANdArd MOdeLS: 10kVA; 14kVA; 18KVA; 22kVA (CONT'D)
10 kVa (8.5 kw)
to be installed in a well ventilated area free of airborne dust,
metal particles or flammable gas, allow at least 4 inches on all sides
4352 btU/hr
Performed on start up, by schedule, on-demand (user configurable)
UpS calculates battery replacement time based upon
battery ambient temperature (lCD display, leD and beeps)
UpS gives indication of internal temperature, alarm when high temp
Static switch <1/4 cycle (50hz: 5 ms/60hz: 4.16 ms)
Factory or authorized service center selectable only
Standard – minimum 3 days memory backup during power loss
Schedule on/oFF operation of UpS using communication software
UpS has option for UpS to start automatically when aC is applied
4 leD's indicating input/output condition, warning and battery operation
run/Stop, Set/monitor, Shift/Select,
14 kVa (11.9 kw)
1
1
60 hz (0 – 40 °C) ; 50hz (0 – 33 °C)
-20 – 40 °C (-4 – 104 °F)
30 – 90% (no condensation)
< 3200 ft. (1000 m) above sea level
50 db (a) maximum @ 1 meter from front panel
6092 btU/hr
Standard
64-Supply mode, 32-back up, 16-Faults
generator compatible
provided – Can be disabled from front panel
Standard – external terminal
16 characters x 2 lines
low, high, mute; Selectable by keypad
Standard – hard wire
Standard – terminal contacts only
Standard (inV, byp, batt, lb, aC, Flt)
Standard
18 kVa (15.3 kw)
22 kVa (18.7 kw)
1
2
7832 btU/hr
Del/(page
down),
reset/(page
1
9600 btU/hr
up)
19