No. MIIXR0002EAC
DICOM CONFORMANCE STATEMENT
MEDIA STORAGE
FOR
TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM
MODEL DFP-2000A
with XIDF-037A and XIDF-038A
or
SRS-1000A
(MIIXR0002EAC)
2001

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba DFP-2000A

  • Page 1 No. MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A SRS-1000A (MIIXR0002EAC) 2001...
  • Page 2 IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation. No. MIIXR0002EAC...
  • Page 3: Table Of Contents

    Table of Contents INTRODUCTION... 1 EFERENCES ... 1 EFINITIONS ... 1 CRONYMS BBREVIATIONS AND IMPLEMENTATION MODEL ... 3 PPLICATION UNCTIONAL EFINITIONS OF 2.2.1 DICOM Recording ... 3 2.2.2 DICOM Reader ... 4 EQUENCING OF 2.3.1 Features... 4 2.3.1.1 Transfer of X-ray Examination... 4 2.3.1.2 Review of X-ray Examination ...
  • Page 4 8.1.1 Media Storage Directory IOD Modules... 9 8.1.2 Media Storage XA IOD Modules... 9 8.1.3 XA IOD Modules ... 10 DICOM F NFORMATION 8.2.1 DICOM File Meta Information of Directory IOD ... 11 8.2.2 DICOM File Meta Information of XA IOD... 11 ASIC IRECTORY NFORMATION...
  • Page 5: Introduction

    1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments. It details the DICOM Service Classes, Information Objects, and Application Profiles which are supported by this product.
  • Page 6: Acronyms, Abbreviations And Symbols

    1.3 Acronyms, Abbreviations and Symbols • American College of Cardiology • American College of Radiology • ASCII American Standard Code for Information Interchange • Application Entity • ANSI American National Standards Institute • Application Profile • CEN TC251 Comite Europeen de Normalisation - Technical Committee 251 - Medical Informatics •...
  • Page 7: Implementation Model

    2 Implementation Model Application Data Flow Diagram Transfer of X-ray Examination Review of X-ray Examination Functional Definitions of AE's 2.2.1 DICOM Recording The DICOM Recording supports the following tasks: • Builds DICOM XA Information Objects. • Creates a DICOMDIR file that represents the contents of DICOM XA Information Objects to be recorded.
  • Page 8: Dicom Reader

    2.2.2 DICOM Reader The DICOM Reader supports the following tasks: • Reads the DICOMDIR file that represents the contents of the data as recorded. • Displays the ordered list of patient and image identifying information or icon images. • Reads the selected image SOP instance from the CD-R media and displays it on the monitor of the DICOM Reader.
  • Page 9: Operation

    2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media. STEP-4: Request recording the transferred images onto the CD-R media. 2.3.2.2 Review of X-ray Examination The operation for manual review of X-ray examination is described below:...
  • Page 10: Ae Specifications

    3 AE Specifications DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and the Media Storage Application Profile. Application Profile Identifier Basic Cardiac X-ray Angiographic Studies on STD-XABC-CD CD-R Media 1024 X-ray Angiographic STD-XA1K-CD Studies on CD-R Media...
  • Page 11: File Meta Information For The Application Entity

    3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relevant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator. This AE reads the DICOMDIR from the CD-R media and reads the SOP instances from the CD-R media.
  • Page 12: Extensions, Specializations, And Privatizations Of Sop Classes And Transfer Syntaxes

    Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set. Note: Settings and changes are performed by Toshiba Service Personnel at the time of installation of the Digital Fluorography System. 7 Support of Extended Character Sets...
  • Page 13: Ray Angiographic Information Object Definition

    8 X-Ray Angiographic Information Object Definition Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Object DICOM File Meta Information Basic Directory File-set Identification Module Information Object Directory Information Module Definition Definition of Specific PATIENT keys...
  • Page 14: Xa Iod Modules

    8.1.3 XA IOD Modules Information Entity Patient Patient Module Study General Study Module Study Patient Study Module Series General Series Module Equipment General Equipment Module Image General Image Module Image Image Pixel Module Image Contrast/bolus Module Image Cine Module Image Multi-frame Module Image Frame Pointers Module...
  • Page 15: Dicom File Meta Information

    DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Attribute Name File Preamble DICOM Prefix Group Length File Meta Information Version Media Storage SOP Class UID Media Storage SOP Instance UID Transfer Syntax UID Implementation Class UID 8.2.2 DICOM File Meta Information of XA IOD Attribute Name...
  • Page 16: Directory Information Module

    8.3.2 Directory Information Module Attribute Name Offset of the First Directory Record of the Root Directory Entity Offset of the Last Directory Record of the Root Directory Entity File-set Consistency Flag Directory Record Sequence >Offset of the Next Directory Record >Record In-use Flag >Offset of Referenced Lower-Level Directory Entity...
  • Page 17: Study Keys

    8.4.2 STUDY keys Attribute Name Study Date Study Time Study Description Study Instance UID Study ID Accession Number 8.4.3 SERIES keys Attribute Name Modality Series Instance UID Series Number Institution Name Institution Address Performing Physician's Name Table 13 Type (0008, 0020) Always set (0008, 0030) Always set...
  • Page 18: Image Keys

    8.4.4 IMAGE keys Attribute Name Instance Number Image Type Image Date Image Time Positioner Primary Angle Positioner Secondary Angle Image Comments Number of Frames Calibration Image Icon Image Sequence >Samples per Pixel >Photometric Interpretation >Rows >Columns >Bits Allocated >Bits Stored >High Bit >Pixel Representation >Pixel Data...
  • Page 19: Xa Information Object Definisions

    XA Information Object Definisions 8.5.1 Patient Module Attribute Name Patient's Name Patient ID Patient's Birth Date Patient's Sex Patient Comments 8.5.2 General Study Module Attribute Name Study Instance UID Study Date Study Time Referring Physician's Name Study ID Accession Number Study Description 8.5.3 Patient Study Module...
  • Page 20: General Series Module

    8.5.4 General Series Module Attribute Name Modality Series Instance UID Series Number Series Date Series Time Performing Physician's Name Series Description 8.5.5 General Equipment Module Attribute Name Manufacturer Institution Name Institution Address Station Name Manufacturer's Model Name Device Serial Number Software Versions 8.5.6 General Image Module...
  • Page 21: Image Pixel Module

    8.5.7 Image Pixel Module Attribute Name Samples per Pixel Photometric Interpretation Rows Columns Bits Allocated Bits Stored High Bit Pixel Representation Pixel Data 8.5.8 Contrast/Bolus Module Attribute Name Contrast/Bolus Agent Contrast/Bolus Route Contrast/Bolus Volume Contrast Flow Rate(s) 8.5.9 Cine Module Attribute Name Frame Time 8.5.10...
  • Page 22: X-Ray Image Module

    8.5.11 X-ray Image Module Attribute Name Frame Increment Pointer Image Type Pixel Intensity Relationship Samples per Pixel Photometric Interpretation Bits Allocated Bits Stored High Bit Pixel Representation Reference Image Sequence >Reference SOP Class UID >Reference SOP Instance UID 8.5.12 X-ray Acquisition Module Attribute Name Radiation Setting X-ray Tube Current...
  • Page 23: Xa Positioner Module

    8.5.13 XA Positioner Module Attribute Name Distance Source to Detector Estimated Radiographic Magnification Factor Positioner Motion Positioner Primary Angle Positioner Secondary Angle 8.5.14 Curve Module Attribute Name Curve Dimensions Number of Points Type of Data Axis Units Data Value Representation Curve Data Descriptor Coordinate Start Value Coordinate Step Value...