Toshiba Portege R200 Maintenance Manual page 53

Personal computer
Hide thumbs Also See for Portege R200:
Table of Contents

Advertisement

2.3 Power Supply Troubleshooting
PTV output
Error code
A0h
A1h
A2h
A3h
Check 2
In the case of error code 10h or 12h:
Make sure the AC adapter and AC power cord are firmly plugged into the DC
IN 15 V socket and wall outlet. If the cables are connected correctly, go to the
following step:
Connect a new AC adapter and AC power cord. If the error still exists, go to
Procedure 5.
Check 3
In the case of error code 21h:
Go to Procedure 3.
Check 4
For any other errors, go to Procedure 5.
PORTEGE R200 Maintenance Manual (960-519)
Meaning
PTV voltage is over 1.26V when the computer is powered on/off.
PTV voltage is under 0.89V when the computer is powered on.
PTV voltage is under 0.89V when the computer is booting up.
PTV voltage is over 0.89V when the computer is powered off.
2 Troubleshooting
[CONFIDENTIAL]
2-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents