(3) Verifying the parameter settings stored on a USB memory device with those in an inverter
Copy the parameter settings of the source inverter to a USB
1
memory device. (Refer to
Connect the FR-LU08(-01) and a USB memory device to the
2
target inverter.
Display the Function menu, turn
3
[USB Memory Device], and press
Turn
to move the cursor to
[USB Parameter Copy], and
4
press
.
(SET)
Move the cursor to [File Name
Select], and press
.
(SET)
5
A file name selection screen
appears. Turn
to move the
cursor to the target file, and
6
press
.
(SET)
page
38.)
to move the cursor to
.
(SET)
USB Memory Device
USB Parameter Copy
PLC Project Copy
STOP
PU
BACK
S E T
SET
N E X T
USB Parameter Copy
AutoNumberedNewFile
File Name Select
PU
STOP
BACK
S E T
SET
N E X T
USB Parameter Copy
File Name Select
CP001
STOP
PU
BACK
S E T
SET
N E X T
Turn
to move the cursor
to [3: Verify], and press
7
(SET)
A confirmation screen
appears for execution.
Press
to execute the
8
(SET)
verification.
If a verification error occurs,
the verification is stopped and
an error screen appears.
Press
to continue the
9
(NEXT)
verification.
Press
to end the
(ABORT)
verification.
NOTE
• If an error occurs in verification on items other
than parameters, such as the setting frequency,
only [Verify Error] is displayed.
USB Pr. Copy: CP001
1 : Copy INV to USB
2 : Write USB to INV
.
3 : Verify
STOP
PU
BACK
S E T
SET
N E X T
USB Pr. Copy: CP001
3 : Verify
SET
: Execution
BACK : Cancel
STOP
PU
BACK
S E T
N
SET
X T
USB Pr. Copy: CP001
Verify Error
1 Max. frequency
- - -
- - -
S T O P
S T O P
P U
P U
N E X T
S E T
S E T
S E T
ABORT
MENU
3