Model Selection Guide - Honeywell DirectLine DL424 User Manual

Sensor module for dl 5000 dissolved oxygen probes
Table of Contents

Advertisement

Introduction

1.5 Model Selection Guide

Instructions
Select the desired key number. The arrow to the right marks the selection available.
Make the desired selections from Tables I through IV using the column below the
proper arrow.
A dot ( ) denotes availability.
Key Number
I
_ _ _ _ _
-
_
Key Number - DirectLine
(Specify electrodes/cells/probes separately)
pH
ORP
Conductivity
DO - PPM
DO - PPB
TABLE I - OUTPUT CABLE
Output Cable for
None (replacement module or customer supplied output cable)-Note 1
Integral or Remote
Cordset - 6m (19.7 ft.) - includes connector and cable - Note 2
Mounting
Field Wiring Connector only - customer supplies cable only-Note 2
TABLE II - SENSOR CABLE/REMOTE CONNECTOR (between electronic module and electrode, sensor or pro
Integral Mounting
Remote Mounting Cable
- Durafet only
Remote Mounting
Connector (Cable is
supplied with sensor or
probe)
TABLE III - REMOTE MOUNTING OPTIONS
Mounting Kit for
Remote Mounting
TABLE IV - OPTIONS
Tagging
Certificates
Notes:
1 Customer supplies cordset or cable with M12 connecter. Suppliers & P/Ns include:
Cord--set
M12 Field Wiring Connector
Cable
2 Recommended cable is 2-wire twisted shielded pair
RESTRICTIONS
ORDERING INSTRUCTIONS:
1. Part numbers are provided to facilitate Distributor Stock.
2. Orders may be placed either by model selection or by part number.
3. Part numbers are shown within the model selection tables to assist with compatibility information.
4. Orders placed by model selection are systematically protected against incompatibility.
5. Compatibility assessment is the responsibility of the purchaser for orders placed by part number.
6. Items labeled as N/A are not available via the stocking program and must be ordered by model selection.
4
II
III
IV
-
-
_
_
-
_ _ _ _
®
Sensor Electronics Module
For use with Durafet II, Meredian II & HPW7000 pH electrodes
For use with ORP electrode.
For use with Contacting Conductivity Cells
For use with Dissolved Oxygen ppm Probes
For use with Dissolved Oxygen ppb Probes
No cable or connector required
6,096m (20 ft.) of sensor cable - Durafet II Remote Mounting
15,24m (50 ft.) of sensor cable - Durafet II Remote Mounting
Remote Mounting Connector - Meredian II pH
Remote Mounting Connector - Meredian II ORP
Remote Mounting Connector - HPW7000
Remote Mounting Connector - Conductivity
Remote Mounting Connector - Dissolved Oxygen
None Integral unit - mounting not required
2" (5,08 cm) Pipe mtg. bracket, wall mtg, & DIN Rail clip
None
Linen Customer ID Tag - 3 lines w/22 characters/line
SS Customer ID Tag - 3 lines w/22 character/line
None
Calibration & Conformance
Phoenix Contact
SAC-3P-5.0-PUR/M12FSSH Stainless
SACC-M12FS-4CON-PG7
Restriction
Available Only With
Letters
Table
Selection
Table
d
IIl
A
e
III
B
DirectLine® DL424/425 Sensor Module User Manual
Turck
RKV4T-6/S618
B8141-0
2-wire twisted shielded pair
Not Available With
Selection
Selection
Availability
DL421
DL422
DL423
DL424
DL425
D
E
F
0
d
d
d
d
d
1
e
2
e
3
e
3
e
4
e
5
e
6
e
e
A
B
00 _ _
LT _ _
SS _ _
_ _ 00
_ _ CC
9/11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Directline dl425

Table of Contents