6.3

Key to parameters

Model 245 and model 246 (appliance 1)
Parameter
Function
Operating
mode for
appliance 1
Unit for time-
dependent
operation for
appliance 1
Tariff for time-
dependent
operation for
appliance 1
Unit for
consumption-
dependent
operation for
appliance 1
Tariff for
consumption-
dependent
operation for
appliance 1
Current
response
threshold for
appliance 1
consumption
display for
appliance 1
For setting the operating mode to time-
dependent (0) or consumption-dependent (1)
Unit of time for appliance 1 "time-dependent"
operating mode. Defines the length of time (e.g.
1 hour) during which the tariff in P13 is valid.
Tariff for appliance 1 "time-dependent" operating
mode. Debit for (e.g. 1 hour) washing/drying
Unit of time for appliance 1 "consumption-
dependent" operating mode. Defines the length
of time (e.g. 1 hour) during which the tariff in
Tariff for appliance 1 "consumption-dependent"
operating mode. Debit for (e.g. 1 hour) washing/
drying according to time defined in P14.
Current response threshold for appliance 1
"consumption-dependent" operating mode.
Changing the current response threshold deter-
mines the point of power consumption from
Power
Shows the power being consumed. This param-
eter cannot be changed. If a value greater than
1.0 A is measured,
Description
operation
according to time defined in P12.
P15 is valid.
which debiting begins.
6 Settings
is displayed.