Husqvarna DMS 240 Operator's Manual page 33

Hide thumbs Also See for DMS 240:
Table of Contents

Advertisement

Available languages

Available languages

To adjust the angle of the drill column
1. Loosen the screws that lock the drill column and set
the applicable drill angle.
2. Use the angle indicator for approximate adjustment.
If higher precision is necessary, use alternative
methods to measure.
3. Tighten the lock screws of the drill column. Use the
feed lever. The drill column can be tilted 0-60°.
To connect the water supply
1. Connect the water connector to the water supply (A).
898 - 002 - 20.06.2019
2. Open the water system (B). Refer to
drill motor on page 37 for maximum water pressure.
To start the product
CAUTION Do not use more force than
necessary. This only makes the operation
slow and cause overload to the motor.
CAUTION Use especially very small
pressure where there are rebars. High
pressure against rebars releases the
residual-current device.
1. Start the water system.
2. Push the power switch fully.
3. Let the motor speed increase to the maximum speed
before the drill bit comes in touch with the workpiece.
4. Push the drill bit on to the workpiece with the feed
lever.
5. Use very small pressure initially, this is to keep the
drill bit in correct position. Then continue as usual.
6. If the residual-current device releases, remove the
drill bit from the workpiece before you reset.
To stop the product
WARNING The drill bit continues to rotate
for some time after the motor stops. Do not
stop the drill bit with your hands. Injuries can
occur.
1. Push the on/off switch to stop the product.
2. Wait until the drill bit has fully stopped.
To decrease the temperature of the
motor
Operate the product with no load for 2 minutes to
A
decrease the temperature of the motor.
B
Technical data -
33

Advertisement

Table of Contents
loading

Table of Contents