SAFETY WARNING AND PRECAUTIONS:

WARNING: The machine has been tested with Mastercool flushing fluid. We do not recommend using this machine with
any other flushing fluid.
WARNING: DO NOT run the pump dry. The seals and bearings will be damaged and will waive warranty.
WARNING: This machine is not intended to be used to flush assembled systems. Do not flush filter/dryers. Do not flush
orifice tubes, TXV valves, or capillary tubes. For best results, flush each component individually.
WARNING: Do not use purge gas that is over 90 PSIG (6.2 BAR).
WARNING: The used flushing fluid must be disposed of by following state or national hazardous fluid disposal regulations.
WARNING: Do not use this machine with highly flammable fluids.
WARNING: Wear proper personal protection equipment – gloves and eye protection – when using the machine.
WARNING: Always plug the machine into a properly grounded socket.
WARNING: Depending on the flush fluid that is used, Mastercool recommends that all internal components of the
machine including hoses and motor are completely flushed out and purged after each use due to potentially corrosive
characteristics.
2
4
7
6
8
9

FEATURES AND FUNCTIONS:

1. Internal tank
2. Flush fill cap
3. Flush return cap
4. Hose for fluid flow out of machine
5. Hose for fluid flow into machine
6. External tank connection
7. External tank control valve
3
1
5
10
11
12
8. Flush control valve
9. Purge control valve
10. Purge source control valve (EU only)
11. Purge gas connection
12. Filter screen cap
13. Pump on/off switch
www.mastercool.com