Replacing A Hard Disk Drive In The Raid System (Auto Rebuild) - NEC Express5800/E120d-1 User Manual

Hide thumbs Also See for Express5800/E120d-1:
Table of Contents

Advertisement

Chapter 2 Preparations

1.11.3 Replacing a hard disk drive in the RAID System (Auto Rebuild)

In the RAID System, you can use the auto rebuild feature to restore data back to the state before a failure
occurred.
The auto rebuild feature is enabled in logical drives set to RAID 1, RAID 5, RAID 6, RAID 10, RAID 50, and
RAID60.
The disk array is automatically rebuilt when hot swapping (replacing a hard disk drive while the power on) a
failed hard disk drive.
During the auto rebuild, DISK LED on the hard disk drive flashes green and amber alternately to indicate
that the auto rebuild is being performed.
Observe the following precautions whenever executing the auto rebuild
Do not turn off the server until the auto build completes after a hard disk drive fails.
Leave an interval of at least 90 seconds between a hard disk drive removal and a hard disk drive
installation.
Do not replace a disk during the auto rebuilding of another hard disk drive (during an auto rebuild, DISK
LED on the hard disk drive flashes green and amber alternately).