7 Reference Drawings
7.3 MIWI350 as Power or Communication Box

7.3.1 Barrier Connections

7.3.1.1 With CloudLink Modem

40-6184
40-6182
RS485 CONNECTIONS
CL R100 SERIAL CONNECTOR
COLOR
BLACK
PIN 1 (GND)
WHITE
PIN 2 (TXD/A)
PIN 3 (RXD/B)
RED
DETAIL H
H
CASE CONNECTOR PINOUT
CASE CONNECTOR
FUNCTION
A: WHITE
DO NOT USE
RXD/B
B: RED
C: BLUE
DO NOT USE
D: BLUE
MPC+
E: BLACK
MPC-
F:BLACK
TXD/A
NOTE: CUT THE CONDUCTORS AND COVER THE "DO NOT USE" PINS WITH INSULATION TAPE
ROUTE THE CABLE THROUGH THE PD BOARD PLATE SLOT
AND CONNECT AS SHOWN.
Figure 7-5: Internal Wiring - CloudLink R100 Connections
DO NOT CONNECT BLACK WIRE OF 40-6184.
CUT THE STRIPPED CONDUCTORS AND ADD INSULATION TAPE
22-1350
RED
BLACK
RED
WHITE
RED
BLACK
40-6167-1
40-6167
40-6043-1
CASE CONNECTOR TO BARRIER CONNECTION
22-3037
20-3827
Honeywell
40-2342-1
BLACK (MPC-)
BLUE (MPC+)
BLACK
RED
| 29