Seaira Global WatchDog 900c Cleaning Manual

How to clean the pump
Hide thumbs Also See for WatchDog 900c:

Advertisement

Quick Links

WatchDog 900c:
How to Clean the Pump

Tools:

• Phillips Head Screwdriver
-OR-
• #2 Phillips Drill
• Cleaning Solution (choose one of the following) :
• Option #1- (4 ounces white vinegar) + (12 ounces water)
• Option #2- (1 ounce bleach) + (15 ounces water)
• 32 ounces clean water
1. First, mix your cleaning solution using one of the options listed above.
2. Next, you will need to open the drain side end cap so you have access to the drain tray. To
do this, use the screwdriver or drill to remove the screws (one on each side of the end cap).
NOTE: If you have moved your dehumidifier out of the crawl space, make sure the drain line has
somewhere to drain, prior to proceeding to the next step.
3. Once the end cap is open, press the drain button on the display to drain the reservoir.
Disconnect power to the dehumidifier.
4. Next, slowly pour the cleaning solution into the drain train. Continue pouring all of the
cleaning solution, moving from side to side to evenly distribute it.
Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445
2
www.seairaglobal.com
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WatchDog 900c and is the answer not in the manual?

Questions and answers

Summary of Contents for Seaira Global WatchDog 900c

  • Page 1 4. Next, slowly pour the cleaning solution into the drain train. Continue pouring all of the cleaning solution, moving from side to side to evenly distribute it. Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445 www.seairaglobal.com...
  • Page 2 5. Pour the clean water into the drain tray, until you hear the pump activate twice (normally 16-32 ounces) 6. Finally, close up the end cap, and secure the two screws (one on each side). Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445 www.seairaglobal.com...
  • Page 3 2. Unplug the dehumidifier and remove the cover so you have access to the pump. 3. Remove the pump head from the reservoir by unscrewing the screw. Wipe the reservoir clean with a paper towel. Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445 www.seairaglobal.com...
  • Page 4 4. Fill the pump reservoir with the cleaning solution. 5. Reassemble the pump, then use the manual drain button to flush mixture through the discharge tubing. Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445 www.seairaglobal.com...
  • Page 5 NOTE: If you get any of the cleaning solution on the coils, flush with water. 7. Pour sufficient clean water through the drain pan to allow the pump to turn on twice. 8. Reassemble the unit. Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445 www.seairaglobal.com...