Thank you for purchasing OLYMPUS Micro cantilever.
Please read this manual carefully before use.
<Explanation of the each part of the products>
Cantilever chips in a plastic case are included in the envelope with manual and spec. sheet.
Label
Inside
Envelope for transportation
Cantilever chips are contained in the plastic case.
Case for transportation (plastic)
Label side
Arrow mark
Hold position
Case (closed)
Case label
user's manual
user's manual 書
Manual and Specification sheet
Plastic pack (translucent blue)
Plastic case
(Cantilever chips are in the case)
Cover
Bottom Cover
Down side
Cantilever strips
Case (open)
Cantilevers are tip-side-up
as viewed in the case.
Case label
Products name
OTR8-PS-W
Lot. Number
- 1e -
Please obey the following to the OLYMPUS micro cantilevers
 Use protective eye glasses when handling to avoid
damage to the eyes from breakage of the cantilever
chips.
 Use protective gloves to avoid getting hurt by a shard of cantilever chip,
when breaking and cutting cantilever chips from cantilever strips.
 Please handle our cantilevers carefully because they are fragile.
Upside
 Do not drop or shake the cantilever case. Even when the cantilever
strips are contained in the cantilever case, the cantilever strips may
move in the case and the cantilever may break if the case is handled
roughly or jarred.
 Be sure to store the cantilevers at room temperature and
moderate humidity.
Inspection
stamp
 When discarding, please obey the laws and regulations in your country
and/or your company. These cantilevers are made from silicon nitride,
gold/chromium and pyrex glass.
Warning
Warning
Caution
Caution
Caution
Caution
- 2e -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OMCL-TR800PSA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Olympus OMCL-TR800PSA

  • Page 1 Please obey the following to the OLYMPUS micro cantilevers user’s manual user’s manual 書 Warning Thank you for purchasing OLYMPUS Micro cantilever. Please read this manual carefully before use.  Use protective eye glasses when handling to avoid damage to the eyes from breakage of the cantilever chips.
  • Page 2 4) Peel off the tape to open the case. Don’t throw away the tape. That will be used again to fix See the specification sheet of OLYMPUS Micro cantilevers at the last page of this manual. Label Hold position (Bottom Cover)
  • Page 3 Preparation before disconnecting the cantilever chip 6) In the procedure 1) to 3) in the drawing below, open the cover and take out the cantilever strip with tweezers. Caution If you find the cantilever strip attached to the back side of the cover, stop opening the cover. Close the case again and pat the cover with your finger to move the cantilever strip from the cover to the bottom cover.
  • Page 4 Attaching the cantilever chip to your instrument 2) Turn the microscope slide glass sideway for disconnecting a chip (see below). Then, cantilevers on a chip end face to you (see right below). 1) After reading the instruction manual of your instrument again, grasp the side of the cantilever chip with the tweezers and attach the cantilever chip to your scanning probe microscope.
  • Page 5 Microscope slide glass Rest of cantilever strip email : probe@olympus.co.jp Please access to the web page of OLYMPUS micro cantilevers. http://www.olympus.co.jp/probe The way to store the rest cantilever strip in the case 3) Attach the microscope slide glass on the case with a Scotch drafting tape.

Table of Contents