Mitsubishi Electric MS-30SV-A1 Service Manual page 37

Table of Contents

Advertisement

TEST POINT DIAGRAM AND VOLTAGE
MS-30SV -
A1
Indoor electronic control P.C. board
Fuse (F11)
250V AC 3.15A
How to set "Auto restart function"
Cut the Resistor JR07. (Refer to page 25.)
37
Fan motor power supply
}
Power supply input
240V AC
}
+
Room temperature
thermistor(RT11)
Indoor coil
thermistor(RT12(main))
Indoor coil
thermistor(RT13(sub))
Emergency operation
switch
Timer short mode point
(JPS, JPG)
(Refer to page 24.)
+
12V DC
Indoor coil thermistor(RT12(main), RT13(sub))
Room temperature thermistor (RT11)
5V DC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mu-30sv-a1

Table of Contents