LA10016
A ring failure condition was detected while attempting to insert into the network.
Explanation: The token-ring network is not functioning correctly.
User Action: Contact your local network administrator to determine the status of your network, or try connecting
again at a later time.
LA10017
A ring beaconing condition was detected while attempting to insert into the network.
Explanation: The token-ring network is not functioning correctly.
User Action: Contact your local network administrator to determine the status of your network, or try connecting
again at a later time.
LA10018
A duplicate network address was detected while attempting to insert into the network.
Explanation: The address specified for the NetAddress configuration parameter is being used by another adapter (or
ring station) on the network.
User Action: Modify the configuration file to change the NetAddress parameter value being used for this adapter, or
remove the NetAddress parameter to allow the adapter's universally administered address to be used.
Contact your local network administrator for assistance with choosing a new NetAddress parameter value, or with
having the conflicting adapter removed from the same token-ring network as this adapter.
LA10019
A ring parameter failure occurred while attempting to insert into the network.
Explanation: The token-ring network is not functioning correctly.
User Action: Contact your local network administrator to determine the status of your network, or try connecting
again at a later time.
LA10020
The adapter was forced to remove itself while attempting to insert into the network.
Explanation: The token-ring network rejected the attempt by this adapter to connect to it.
User Action: Contact your local network administrator to determine the status of your network, or try connecting
again at a later time.
LA10021
A hardware failure occurred while attempting to open the adapter.
Explanation: A hardware error was detected when opening the adapter for network operation.
User Action: Run the diagnostics program to isolate the problem, and contact your support personnel. If no problem
was identified by the diagnostics, check that the cable is attached securely to both the adapter and the network
interface (wall plate). Switch the computer OFF and then ON again to restart the machine. If the problem persists,
contact your support personnel.
LA10022
A hardware failure occurred while attempting to open the adapter.
Explanation: A hardware error was detected when opening the adapter for network operation.
User Action: Run the diagnostics program to isolate the problem and contact your support personnel. If no problem
was identified by the diagnostics, check that the cable is attached securely to both the adapter and the network
interface (wall plate). Switch the computer OFF and then ON again to restart the machine. If the problem persists,
contact your support personnel.
LA10023
The adapter cannot be opened in AutoSense mode if it is the only active station on the network.
Explanation: The adapter DataRate configuration parameter is set to Auto (which is also the default value if the
parameter is not specified), but the adapter is the first station to open on the token-ring network.
User Action: This adapter is designed to not open onto the attached token-ring network if it is configured to use
AutoSense detection and if it would have been the first active ring station.