Log Sheet For Programmed User Functions - Siemens FC1008-A Technical Specification

Fire control unit
Table of Contents

Advertisement

Configuration
8.4

Log sheet for programmed user functions

Installation: ..................................................................................................................
Programming steps and functions
1
Timer V1
2
Timer V2
3
Processing of zone Alarm (zone type)
4
LED activation mode
LED Remote transmission
LED Alarm
LED System part disabled on mode manned
No Resound or not on new alarm
5
Activation mode of control lines 1 – 6
6
Measures against false alarms
alarm verification
zone disabled in mode manned
7
Control lines on Alarm
8
Special zone parameters
behavior on immediate Alarm after Reset
function of zone control outputs
9
Not used
10
Detector line evaluation on line short or line
break
11
Cross-zoning
12
Access code (password)
operating access
13
Special PMI parameters
reminder beep on fault and system part dis-
abled
Fault messages to be Reset
14
Not used
15
Special parameters
external Acknowledge and Reset
zones with special disabling procedure
Remote transmission on operating access
all zones with option 1 in step 3 react like
option 4
16
Programmable control input
40
Building Technologies
Fire Safety & Security Products
Basic programming steps
Factory default setting
1
1
1
1
3
6
7
1
1
3
1
1
3
1
1
1
1
3
3
1
3
5
7
1
Selected pre-setting: ............
Individual settings of a selected pre-setting
min : .....................
min : .....................
Option 1, zone: ................
Option 2, zone: ................
Option 3, zone: ................
Option 4, zone: ................
..................
..................
..................
..................
Line 1, option: ..................
Line 2, option: ..................
Line 3, option: ..................
Line 4, option: ..................
Line 5, option: ..................
Line 6, option: ..................
active zone ......................
active zone ......................
Option 1, zone: ................
Option 2, zone: ................
Option 3, zone: ................
Option 4, zone: ................
Option 1, zone: ................
Option 2, zone: ................
Option 3, zone: ................
Option 4, zone: ................
Option 1, zone: ................
Option 2, zone: ................
Option 3, zone: ................
Option 4, zone: ................
Option 1, zone: ................
Option 2, zone: ................
Option 3, zone: ................
..................
..................
..................
..................
..................
..................
..................
..................
A6V10265083_a_en_--
03.2010

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc1012-aFc1012-bFc1008-bFc1012-cFc1008-c

Table of Contents