Indication of Water Filter

The water filter control will calculate and record the total volume of water flowed through the valve during the
opening periods. The flow rate for the dispenser water valve is 1,51 litres per minute (24-58 cc per second).
The total liters flow is calculated by using the flow rates for Ice Maker valve and Water Dispenser valve.
The litres of each valve flow rate is multipled by the corresponding open time. The total liters
will be obtained adding the liters of each valve. The liters and time usage data will be recorded even after
a power black out. These data will be updated daily.
By pressing the "reset alarm" button for at least 3 seconds the buzzer sounds one time. The water filter icon
switch back to the low usage state.