0-0-0-K
58
Room temperature display
Control profile display
– Simplified temperature adjustment and programming procedure
– 6 pre-defined control profiles, 3 user programmable control profiles
– Protection against freezing
– Temporary set-temperature override
– User selectable temperature span;
User selectable heater/cooler operation mode
– Slim housing design
– EL backlight
Removing of back housing
of Control Centre
1. Push and hold internal lock by a screw driver.
2. Remove the front housing.
Receiver (Power Control Unit)
Front view
Back view

Power switch

LED indicators

LED INDICATORS
There are two LEDs on the Power Control Unit as status indicators:
• Red LED turns on as long as there is power to the unit. When there is no power to the unit or when power switch
on the front cover is put at the OFF position, the red LED is off.
• Green LED turns on as long as the heating/cooling device is energized.
POWER SWITCH
There is a power switch on the Power Control Unit. When there is no demand to turn on the heating/cooling device,
e.g. when you go on holiday, it is recommended to turn the power switch to the OFF position.

INSTALLATION

RF Address Code Setting

If there is another user nearby, e.g. in the next house, your receiver may be faulty triggered by their transmitter.
You may select a different RF address code to prevent this. Receiver can only response to RF coding with the same
address code setting as its own address code.
1. To adjust address code of Power control unit, simply left or right of
the 5 dip switch levers.
2. To adjust address code of Control Centre, open the housing of the
transmitter unit. See removing of back housing of Control Centre
section on how to open the housing.
Caution:
1. Address code of Control Centre must be the same as address code
of Receiver. For any ON position of address code # in Control Centre,
the same address code # of Receiver must be switched to ON.
2. Disconnect AC power and remove batteries prior to adjusting address
code.
Removing your old thermostat
CAUTION: to avoid electric shock, isolate the power of the heating/cooling system at the main power box in your home.
Read the following instructions carefully before disconnecting the wires.
1. Turn off your old thermostat.
2. Remove the cover from the old thermostat.
3. Unscrew the old thermostat from the wall plate.
4. Now find the screws attaching the wall plate to the wall, and remove them. You should now be able to pull the
wall plate a small distance from the wall. Do not disconnect any wire yet, simply locate the wires.
Push and
Remove the front
hold internal
housing