Technical Data; Equipment; Power Supply; Ambient Conditions - Bosch Rexroth IndraControl L10 Project Planning Manual

Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraControl L10
4

Technical Data

4.1

Equipment

4.2

Power Supply

4.3

Ambient Conditions

Processor
Random access memory
(RAM)
Interfaces:
Interface to I/O modules
Communication interface
Inputs and outputs
Fig.4-1:
Equipment
The IndraControl L10 is supplied with 24 V. The following values of the oper‐
ating voltage comply with DIN EN 61131-2:
Nominal value
Tolerances
Residual ripple
Umax
Umin
Fig.4-2:
Operating voltage according to DIN EN 61131-2
Three operating voltages can be applied on the IndraControl L10 (refer to
chapter 7.2.1 "External Supply Voltages" on page
from these voltages is as follows:
Current consumption by U
LS
Current consumption from U
U
S
Fig.4-3:
Current consumption
The power consumption of the IndraControl L10 (no I/O connected)
is normally 4.6 watt.
Max. ambient temperature
Relative humidity
Electric Drives
| Bosch Rexroth AG
and Controls
STMicroelectronics ST40with at least 192 MHz
At least 32 Mbytes DRAM and at least 32 Kbytes
NvRAM
Rexroth Inline interface
1 x Ethernet connection (RJ 45, 10/100 Base-T)
8 electrically isolated digital inputs
4 electrically isolated digital outputs
24 VDC
-15 % / +20 % (without residual ripple)
+/-5 %
30 V
19.2 V
1.25 A max
and
Max. of 8 A in total
M
In operation
+5 ... +55 °C
RH-2; 5 % to 95 % acc. to
DIN EN 61131-2,
Condensation not al‐
lowed.
15/54
Technical Data
24). Current consumption
Storage / Transport
-25 °C bis +70 °C