  • Page 1 L a C o r n u e 2 0 0 8 1 9 0 8 C o r n u e 1 9 0 8 M a i n t e n a n c e m a n u a l H Â...
  • Page 2 2. Adjustment of the low settings ............2 3. Fuel conversion ................3 4. Gas Pressure Regulator ..............5 ©2008 - LA CORNUE - Maintenance Manual Broche Flamberge Centenaire USA December 2008 - Anna K. 08NOTMAINBFG100/UL-1 M M a a i i n n t t e e n n a a n n c c e e M M a a n n u u a a l l B B r r o o c c h h e e F F l l a a m m b b e e r r g g e e...
  • Page 3 Important information AINTENANCE 1. I MPORTANT INFORMATION Model BFG- -00U00 Electrical Power 15.5 Watts (120 V a.c.) Natural Gas Pressure 5" W.C. Input Rating 27,000 BTU/hr Propane Gas Pressure 11" W.C. Input Rating 25,000 BTU/hr Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
  • Page 4 Adjustment of the low settings AINTENANCE Remove the control knob again, and rotate the split screw on the valve body to the left to increase the flow rate, to the right to reduce it. Re-install the knob to turn the burner off. Re-install the valve cover and the control knobs by screwing in the appropriate screws.
  • Page 5 Fuel conversion AINTENANCE The orifices are always replaced in the following sequence: Remove the back panel by unscrewing the screws that keep it in place. Screw the adjusting cone (2) and insert it into the mixing tube in order to free sufficient space for unscrewing the orifice.
  • Page 6 Gas Pressure Regulator AINTENANCE 4. G RESSURE EGULATOR For proper operation, the pressure of natural gas supplied to the regulator must be between 6’’ and 10’’ of water column. For LP gas, the pressure supplied must be between 12’’ and 13’’ of water column. When checking for proper operation of the regulator, the inlet pressure must be at least 1’’...
  • Page 7 This equipment is design-certified by a Nationally Recognized Testing Laboratory to the appropriate National Standards as indicated on the Equipment Rating Plate. Any modification without written permission of the La Cornue Company voids the certification and warranty of this equipment.
  • Page 8 14, rue du Bois du Pont - Z.I. les Béthunes 95310 Saint-Ouen l'Aumône - FRANCE Postal address : La Cornue SAS - B.P. 99006 95070 Cergy Pontoise Cedex - FRANCE Phone : + 33 (0)1 34 48 36 36 - Fax : + 33 (0)1 34 64 32 65 E-mail : a.table@la-cornue.com...