Remote Instrument Controller - Honeywell PRIMUS 1000 Pilot's Manual

Integrated avionics system for the citation encore
Hide thumbs Also See for PRIMUS 1000:
Table of Contents

Advertisement

Remote Instrument Controller

The remote instrument controller, shown in Figure 3–15, selects course
and heading for display on the HSIs. The functional controls are listed
below.
D
COURSE Knobs – The COURSE knobs set the VOR navigation
course. When the course is set, the remote instrument controller
transmits course data to the display controller. The display controller
in turn transmits the data to the IAC for the EFIS and flight director
function. The left COURSE knob controls the pilot's side course
selection. The right COURSE knob controls the copilot's course
selection.
Push either the left or right
course arrow display with a TO flag on the HSI. This function is
inhibited when ILS or FMS is displayed.
D
HEADING Knob – The HEADING knob sets the heading bug on
both HSIs. When the heading bug is set, the symbol generator
transmits heading signals to the flight director computer.
Pushing the
PUSH SYNC
the present heading (HSI lubber line).
A28–1146–134
REV 1 Jan/03
PRIMUS
Remote Instrument Controller
Figure 3–15
PUSH DIR
button synchronizes the heading bug to
R
1000 Integrated Avionics System
button to center that side's
Electronic Flight Instrument System (EFIS)
AD–63825@