Technical Specifications; Nvo5-151*-Pf - Pepperl+Fuchs LAL-SRW-08 Manual

Table of Contents

Advertisement

Available languages

Available languages

ALARM SYSTEM

Technical specifications

7
Technical specifications
7.1

NVO5-151*-PF

EN
Power supply
Rated voltage
Power consumption
Max. fusing
Overvoltage category
Connection
Safety maximum voltage U
Output
Connection for relay 1
Connection for relay 2
Output
Contact loading
Safety maximum voltage U
Galvanic isolation
Output/power supply
Output/output
Mechanical data
Mass
Protection class
Mounting
Dimensions
Ambient temperature
Connection for overflow sensor
Connection
U
I
o
P
o
C
L
o
28 - EN
m
m
o
o
230 V AC, 50 Hz ... 60 Hz
6 VA
10 A
III
terminals 5, 6, 7
253 V
terminals 1, 2, 3
terminals 10, 11, 12
potential free changeover contact
250 V AC/4 A/100 VA
253 V
reinforced insulation according to EN 50178, rated insulation
voltage 300 V
eff
approx. 325 g
IP20
DIN rail
warning device 70 mm x 86 mm x 58 mm
housing NV05-KV 110 mm x 200 mm x 100 mm
-25 °C ... +60 °C
terminals 13, 15,
21.2 V
270 mA
1.4 W
0.6 µF
0.5 mH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lal-srw seriesLal-srw-01Lal-srw-18

Table of Contents