Table 1: Loop Resistance per 1000 feet
Wire Type
24 AWG /0,53 mm
23 AWG /0,57 mm
22 AWG /0,64 mm
Table 2: Power Distance Chart
Power Supply Voltage
Voltage at the Camera
100 mA Camera
300 mA Camera
1 AMP Camera
Important Safety Warnings
•
Installation should be made by a qualified service person and should
conform to all local codes.
•
DO NOT bundle UTP signals in the same conduit as high-voltage wiring.
•
To reduce the risk of fire or electrical shock, do not expose these products to
rain, moisture, dripping or splashing.
•
No objects filled with liquids, such as vases, shall be placed on GE equipment.
•
DO NOT block ventilation openings to let sufficient airflow to the UTP devices.
•
The Main fuse for models with built-in AC power supply is 5 A at 110 VAC or
at 3 A 220 VAC. Each camera power fuse is 2 A and can be accessed by
removing the front panel. Fuses may be replaced by a qualified service
person only when the unit is off and AC power cord is unplugged.
•
Use only the power cord and plug supplied with the unit for connecting to AC
outlets.
•
Only unplugging the power cord is considered as a main power disconnect.
4 of 11
Resistance
52 ohms
42 ohms
33 ohms
Dual 24 AWG
448 ft. / 137 m
Dual 23 AWG
564 ft. / 172 m
Dual 24 AWG
150 ft. / 46 m
Dual 23 AWG
190 ft. / 58 m
Dual 24 AWG
46 ft. / 14 m
Dual 23 AWG
58 ft. / 18 m
12 VDC
24 VAC
10.8 VDC
21.6 VAC
896 ft. / 273 m
1,130 ft. / 345 m
300 ft. / 92 m
378 ft. / 115 m
90 ft. / 28 m
114 ft. / 35 m
P/N 1069686 • REV 1.0 • ISS 10MAR10
28 VAC
21.6 VAC
2,388 ft. / 728 m
3,012 ft. / 918 m
796 ft. / 243 m
1,004 ft. / 306 m
240 ft. / 73 m
300 ft. / 92 m