Siemens SIMATIC Box PC 620 Manual page 150

Hide thumbs Also See for SIMATIC Box PC 620:
Table of Contents

Advertisement

Hardware Information
Parallel Port LPT1
The parallel port (LPT 1) on the Box PC has the following pinout:
Figure 7-3 Parallel Port LPT 1 (Socket)
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18 - 25
7-16
www.aotewell.com
1
13
Designation
Description
/ Strobe (CLK)
Data message
Data - Bit 0
Data line 0
Data - Bit 1
Data line 1
Data - Bit 2
Data line 2
Data - Bit 3
Data line 3
Data - Bit 4
Data line 4
Data - Bit 5
Data line 5
Data - Bit 6
Data line 6
Data - Bit 7
Data line 7
/ACK
Acknowledge
BUSY
Not ready
PE
No paper
SELECT
Device selection
/ AUTO FEED
Automatic new line
/ ERROR
Device error
/ INIT
Reset / Initialization
/ SELECT IN
Printer selection
GND
Ground
sales@aotewell.com
14
25
Industry Automation
Input / Output
Output (open collector)
Output (TTL level)
Output (TTL level)
Output (TTL level)
Output (TTL level)
Output (TTL level)
Output (TTL level)
Output (TTL level)
Output (TTL level)
Input (4.7 kW pull up)
Input (4.7 kW pull up)
Input (4.7 kW pull up)
Input (4,7 kW pull up)
Output (open collector)
Input (4,7 kW pull up)
Output (open collector)
Output (open collector)
-