Mounting in a separate housing

When installing the 16 I/O module in a separate housing, use a suitable housing from
our catalog.
As per EN, only a MB-Secure housing is permitted.
Permitted
4.3.1
Install 16 I/O module in the housing
ON
1 2 3 4 5
6
7
8
Wall Tamper
4.3.2
Install Tear-off protection
Screw the PCB with the tear-off contact on the spacer to the mounting surface as shown below. The
length of the spacer depends on the used housing (see P02916-47-002-xx).
Distance between the switch and the bottom plate approx. 2 mm or approx. 15 mm between the PCP
top and the bottom plate. Place washer(s) underneath
15 mm
2 mm
Tear-off contact
ON
1 2 3 4 5
6
7
8
Wall Tamper
The complete tear-off protection incl. spacers in various lengths is available as accessory,
Item no. 055140, PU = 5 piece.
Mounting and Connection Instructions IB2 16 I/O Expander
cable length
between control panel and 16 I/O module:
Mount the circuit board on the housing base using the
supplied fixing materials (Lemosa spacing pieces).
Screw the corner of the circuit board marked with PE on the
PE
grounded housing base using a metal screw.
(Grounding and shielding is in accordance with Chapter 5.2.)
Connect the door contact of the housing to the "Tamper"
connection.
15 mm
Connect the tear-off contact to the "Wall" connection.
(ZG20, ZG2, ZG3.1 or ZG4).
to adjust positioning if necessary.
Washer above
Washer(s) below for height adjustment
Bottom plate
Mounting surface
2 mm
max. 1000 m
.