Gsm and ilp5 ethernet communications modules

Advertisement

TO ILP5
RJ45 RECEPTACLE
LYNX TOUCH
ALTERNATE INSTALLATION
CONNECTOR
BOARD
CONNECTOR BOARD
SCREW
Electrical Specifications
GSMVLP5-4G/GSMVLP5CN-4G
Voltage Input
Current
Idle
Average
Peak
ILP5
Voltage Input
Current:
ETHERNET CABLE
ILP5 SPACER
RJ45
RECEPTACLE
ROTATED
TIE
180
WRAP
(1)
(3)
ILP5
RECEPTACLE
LYNX TOUCH
Figure 3. Installing the ILP5 in the LYNX Touch
5V (provided by the control panel)
15 mA, standby
300mA, average transmit
1.6A peak transmit, 25% duty cycle
5V (provided by the control panel)
83 mA, 100 Base T with traffic
41 mA , 10 Base T with traffic
REMOVE ILP5
KNOCKOUT
TIE
WRAP
POINT
LOCKING TABS
REMOVE ILP5
SPACER
5000-100-154-V2