SYSTEM SPECIFICATIONS

Electrical Specification

Power Supply
Current Absorption
Absorbed Power
Fuse (5x20)
Logic
Backup
PC Interface
Baud Rate
Working Noise
Display
Keyboard
Equipment Classification and
Standard Reference
Installation Category
IP Protection
Standard reference

SAFETY REGULATIONS AND OPERATING PRECAUTIONS

The machine should work in a closed room protected from dust and excessive humidity.
The machine should be positioned in such a way that its distance from the walls, doors,
windows, other machines or working positions guarantees immediate access in the case
of urgency, maintenance or repairs.
Do not install this Machine in the neighborhood of other Operating Machines which
produce dust since dust can deposit itself inside the machine and cause damage to the
internal electric devices.
The Machine is furnished with special safety guards which protect the operator from
coming into contact with the mechanical and electrical parts inside the machine. Only
those persons who are specialized in repairs and maintenance and who have been
authorized should have access to the above mentioned parts. Simple general
maintenance can be safely performed by the operator so long as the machine has been
stopped and the electrical power supply has been disconnected.
PES197 & PES197/E: PA25609A01_01
PES197 and PES197/E: ENGLISH
PES197 & PES197/E
117V 60Hz PES197
230 V 50 Hz PES197/E
4 A max
250 W
T 4 A
16 bit Microprocessor
Lithium Battery 3.6 V
RS 232 Asinc. Prog.
Programmable
(supplied at 4800 Baud)
Lower than 73 dB (A)
LCD 2 line for 40 Chars.
21 Programmable keys
PES197 & PES197/E
II
IP 20
IEC EN 50081-1
IEC EN 50082-1
IEC EN 60950 ed. 4th
IEC EN 60204-1

Working Condition

Operating
Temperature
Relative Humidity
Storing
Temperature

Dimensions and Weight

Height
Width
Depth
Weight

Production Capacity

Loading Hopper
Capacity
Unloading Hopper
Capacity
Plate Production
Rate
Page: 6 of 17
PES197 & PES197/E
Listings in ( ) are metric.
+50°
+95° F (+10°
+35° C)
÷
20%
85%
+32°
+122° F (0
+50° C)
÷
PES197 & PES197/E
Listings in ( ) are metric.
11.5" (292 mm)
21" (534 mm)
19" (483 mm)
95 lbs. (43 Kg)
PES197 & PES197/E
Capacity 200 Plates
Capacity 100 Plates
90 Plates per hour,
20 Character Plate