Keyboard Description - Panduit PES197 Manual

Portable embossing system
Hide thumbs Also See for PES197:
Table of Contents

Advertisement

KEYBOARD DESCRIPTION

The following list describes the 6 function keys and their actions:
SETUP: This key is used to access the programming menu or other internal functions of
the machine. A Password enables this command.
CARD TEST: This key enables the production of test plates with a pre-determined format.
It is done without the aid of the computer. Select desired test below; then press ENTER to
produce the plate.
The CARD TESTS for this machine are as follows:
NOTE: Test plates must be run on either MMP350 or MMP350H plates.
CARD TEST 0 – Embosses all the characters in the drum. It will use three plates to do this
CARD TEST 1 – Embosses an "L" in each corner of the plate.
CARD TEST 5 – Will emboss the Mechanical Parameters from the SETUP FILE using two
CARD TEST 6 – Embosses Letters on the plate.
CARD TEST 10 – A drum test embossing characters on two sides of the drum, going back
CARD TEST 11 – Embosses the numbers in the drum.
CARD TEST 14 – Will load and pick the plate, then unload the plate. No embossing.
ABORT: If this key is pressed the current operating cycle will be halted and the plate will be
unloaded.
DUP: If this key is pressed during a READY state and it is followed by ENTER, the
machine will repeat the last processed plate.
PAUSE: If this key is pressed the current operating cycle is blocked. Press START to
continue.
START: Clears any error condition which may have occurred during the current operating
cycle. A corresponding error message will be displayed on the LCD.
FEED: This runs a plate Load/Unload cycle. It can be useful for unloading the last plate at
the end of the work program. This key permits the operator to repeat the last plate should
there have been any error during the production phase.
The keys PAUSE/START and FEED are found on the front panel and the keyboard. They
both activate the same functions which are necessary for plate production. The keyboard is
used only for the machine setup or for diagnostics.
PES197 & PES197/E: PA25609A01_01
PES197 and PES197/E: ENGLISH
since the plates are small and only so many characters fit on each plate.
plates.
and forth.
Page: 11 of 17
7-2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pes197/e

Table of Contents