Figure 11: Removing the Cable
5 Connect the new cable, ensure that the cable orientation is correct with one hole facing out.
Figure 12: Cable Orientation
6 Attach the cable connector to the molex.
Figure 13: Attaching the Cable Connector
7 Reassemble the battery tray by screwing in the three screws.
WARNING: Safety Critical
Use a T6 torx screwdriver with 2.8 +/-0.2 lbf-in torque to ensure that the screws are
tightened.