Connecting A Dc Power Cord - HP 12500 Series Installation Manual

Routing switch
Table of Contents

Advertisement

Figure 44 Connect the AC power cord

Connecting a DC power cord

Six pairs of wiring terminals (marked PSR1 through PSR6) are available on the DC grounding strip of the
12500 switches. The wiring terminals correspond to the power supplies 1 through 6, respectively. The
power source supplies power to the switch through the wiring terminals. If slot 1 is installed with a power
supply, the wiring terminals marked PSR1 must be connected to the power source with a DC power cord
to make the power supply operate properly.
CAUTION:
A plastic protection cover is installed in front of the grounding strip to protect operators from being
shocked. Remove the protection cover before connecting power cords and then install the protection cover
in time.
To connect a DC power cord:
Remove the protection cover from the power supply.
1.
Loosen the fastening screw on the wiring terminal marked with RTN(+) with an M6 wrench, and
2.
remove the screw, spring washer, and flat washer.
1
3
5
16A
2
4
6
7