Environmental Performance Claims for GPS Receiver
Test
Atmospheric Environment
Temperature
Humidity
Mechanical Environment
Vibration
Shock and Bump
Seismic
High Voltage Environment
Dielectric Withstand
High Voltage Impulse
Electromagnetic Environment
High Frequency
Disturbance /
Damped Oscillatory
Wave
Electrostatic
Discharge
Radiated RF
Electromagnetic
Disturbance
Fast Transient
Disturbance
Conducted RF
Electromagnetic
Disturbance
Conducted
Disturbance over
Freq. Range 15Hz to
150kHz
Power Frequency
Disturbance
Standards
IEC60068-2-1/2
IEC60068-2-3
IEC60255-21-1
IEC60255-21-2
IEC60255-21-3
IEC60255-5
IEC60255-5
IEC60255-22-1 Class 3
IEC61000-4-12,
EN61000-4-12 Class 3
IEC60255-22-2 Class 4
IEC60255-22-3 Class 3
IEC60255-22-4 Class 4
IEC60255-22-6 Class 3
IEC61000-4-16,
EN61000-4-16, Class 3
IEC60255-22-7
 25 
Details
Operating range: -10°C to +55°C.
Storage / Transit: -25°C to +70°C.
56 days at 40°C and 93% relative humidity.
Response - Class 1
Endurance - Class 1
Shock Response Class 1
Shock Withstand Class 1
Bump Class 1
Class 1
2kVrms for 1 minute between PSU terminals and earth.
Three positive and three negative impulses of 5kV(peak),
1.2/50µs, 0.5J between all terminals and between PSU
terminals and earth.
1MHz 2.5kV applied to PSU terminals in common mode.
1MHz 1.0kV applied to PSU terminals in differential mode.
0.1MHz 2.5kV applied to PSU terminals in common mode.
0.1MHz 1.0kV applied to PSU terminals in differential mode.
8kV contact discharge.
15kV air discharge.
Field strength 10V/m for frequency sweeps of 80MHz to 1GHz
and 1.7GHz to 2.2GHz. Additional spot tests at 80, 160, 450,
900 and 1890MHz.
4kV, 2.5kHz, 5/50ns applied to PSU terminals in common
mode.
10Vrms applied over frequency range 150kHz to 100MHz.
Additional spot tests at 27 and 68MHz.
Varying voltages applied in common mode as follows:
15Hz to 150Hz: 10V → 1Vrms (20dB/decade)
150Hz to 1.5kHz: 1Vrms
1.5kHz to 15kHz: 1 → 10Vrms (20dB/decade)
15kHz to 150kHz: 10Vrms
300V 50Hz for 10s applied to PSU terminals in common mode.