Correcting Illuminated Defects - Toshiba TLP-X10E Manual

3lcd data projector
Hide thumbs Also See for TLP-X10E:
Table of Contents

Advertisement

Correcting illuminated defects

Control panel
(Main unit side)
AUTO
AUTO
SET
KEYSTONE
VOL/ADJ.
ENTER
EXIT
MENU
INPUT
ON/STANDBY
TEMP LAMP
ON
BUSY
FAN
2
W.BALANCE
STORE IMAGE
ARM LIGHT
LOCK
CAMERA
CAMERA
GAIN
Press both sides
Camera control panel
For the CCD image sensor used in the camera unit, in rare cases some of the pixels may
be disturbed due to the influence of cosmic rays, etc. This disturbance may cause white
spots to appear on the picture.
If white spots appear on the document camera image, use the procedure described below
to correct it.
1
With the document camera operating, fully
cover the camera lens with a piece of black
paper or cloth.
2
Press ARM LIGHT on the camera control panel
ARM LIGHT
and EXIT on the projector's control panel
simultaneously.
You can not use the remote control buttons.
EXIT
Note
Do not press ARM LIGHT and EXIT buttons simultaneously if the camera lens is not
covered. Doing so will not only erase the white spot correction data already set but also
result in parts that are displayed normally being corrected. Also be careful if the camera
input mode is not selected.