3.3.2.Installation

(1) The mounting surface of the equipment must keep good flatness.
When mounting, care should be paid that an excessive force which may caused torsional
distortion on the equipment does not apply to the equipment. The recommended surface
flatness for the mounting surface should be less than 0.2 mm.
(2) Install the equipment with enough space as much as possible in all directions around the
equipment. Care should be paid that the equipment does not touch with peripheral
instruments even if vibration, mechanical shock, etc. are applied to the equipment.
For the maximum dimension of the equipment thickness (12.9 mm), it is recommended that a
clearance more than 0.5 mm should be left the thickness direction.
For the clearance around the front bezel, it is recommended that the clearance more than
0.8 mm should be left in all directions.
(3) Care should be especially paid for the heat effect. Keep the air ventilation and isolate from
heat of the environmental condition. Then, install the equipment where the
environmental temperature at the bottom center of cabinet does not exceed 50
(4) Do not add the force beyond the indicated force on the top and bottom cover of the
equipment. (The restricted force range for the top cover is shown in the Figure 2.)
(For the bottom cover, the applied force should be less than 2N on whole area.)
Figure 2 Restricted force range applied for the top cover
(5) The characteristics of EMC (Electro Magnetic Compatibility) are primarily influenced by the
mounting method of this equipment. Attach this equipment by considering an appropriate
method and structure.
2 N
1 N
R63
0.5 N
R59
R46
Do not add
the force
20
8/28
37
24
5.4
SD-R6112 Rev.1.0
.