Snapshot Detail Description - Toshiba 6F3A4508 Instruction Manual

Maintenance tool for drive
Table of Contents

Advertisement

TOSHIBA

[6-6] Snapshot detail description

This function controls the data record function of the drive equipment which specifies a trigger
condition and saves the specified signal.
The difference with traceback described above is that whereas the trigger condition of traceback is limited to
faults, the user can set the trigger condition freely with snapshot. Also there is a difference in the number of
saved signals (up to 60 signals for traceback and 8 signals for snapshot) and the number of samples that can
be saved (up to 512 samples for traceback and up to 1024 signals for snapshot).
Select Drive Tool/Local Tool/Snap Shot from the menu bar
or click the command button
to select. The following window appears.
Figure 6.6.1 Snapshot
Set the snapshot condition in this window.
1) Number of Signals: Specify the number of signals to save.
For snapshot, you can select from
2 signals 1024 samples
- 36 -
6F3A4508

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wi tool

Table of Contents