2.PRINTER SETUP
2.12 Threshold Setting
(Cont.)
NOTE:
Pressing the [FEED] key one time
causes a –0.1V change, up to 0.0V.
Pressing the [RESTART] key one
time causes a +0.1V change, up to
+4.0V.
(3) Press the [PAUSE] key until the target sensor type is displayed.
<3>ADJUST SET
THRESHOLD<R>1.0V
[PAUSE]
<3> ADJUST SET
THRESHOLD<T>1.4V
(4) Set a threshold voltage (calculated in Sensor Adjustment Menu) by
using the [FEED] or [RESTART] key, as shown below.
Threshold voltage = Midpoint between voltage at a print area and
Black Mark Sensor
THRESHOLD<R>4.0V
THRESHOLD<R>3.9V
THRESHOLD<R>3.8V
THRESHOLD<R>0.1V
THRESHOLD<R>0.0V
(5) After choosing a threshold voltage, press the [PAUSE] key.
(6) To check for a proper operation, issue the pre-printed media in online.
If an error still occurs even after a manual threshold setting, change
the threshold voltage a little, and retry.
E2-82
ENGLISH VERSION EO1-33056
Black Mark Sensor
Feed Gap Sensor
voltage at a gap/black mark
Feed Gap Sensor
[RESTART]
[FEED]
2.12 Threshold Setting
THRESHOLD<T>4.0V
THRESHOLD<T>3.9V
THRESHOLD<T>3.8V
THRESHOLD<T>0.1V
THRESHOLD<T>0.0V