LIMITERS
Test Procedure
Refer to page 3-5 for the procedure for servic-
ing the limiters.
To test a limiter, perform the following steps:
1.
Use an ohmmeter and set the range switch
to R x 1.
2.
Disconnect the wires from the limiter you
wish to test.
All manuals and user guides at all-guides.com
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
4-2
2A
2B
1A
1B
3.
Touch the ohmmeter leads to the indi-
cated limiter terminals. You should obtain
the following readings:
1A to 2A = Continuity (closed contacts)
1B to 2B = Infinity (open contacts)
2A
2B
1B
1A