Handheld Steam Cleaner
by Top Innovations, Inc.
Please read instructions before use.
Mail in your warranty registration card.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC1227 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for McCulloch MC1227

  • Page 1 Model MC1227 Handheld Steam Cleaner by Top Innovations, Inc. Please read instructions before use. Mail in your warranty registration card.
  • Page 2 Handheld Steam Cleaner’s light weight and compact size make it quick and convenient to store. Top Innovations, Inc. would like to invite you to take advantage of our Customer Support web site at: On this website you will find additional information about many other...
  • Page 3: Customer Support

    We can ship most parts directly to your door. To ensure prompt and accurate service, call for a Return Authorization number before returning any unit to Top Innovations. Failure to obtain a Return Authorization number will cause a delay in warranty or out-of-warranty service requests.
  • Page 4 A three-prong outlet or a properly grounded adapter is necessary when using MC1227 Handheld Steam Cleaner. 6. In order to unplug MC1227 Handheld Steam Cleaner, grasp plug and pull smoothly and firmly from outlet. DO NOT attempt to unplug unit by pulling or tugging on cord.
  • Page 5: Important Safeguards

    14. DO NOT operate unit if steam opening is blocked. Should this occur, shut unit off and unplug. 15. Store your MC1227 Handheld Steam Cleaner in a cool, dry place. Allow unit to cool completely, and always drain Water Reservoir before storing.
  • Page 6 The following features and accessories come with your steam cleaner. Carefully inspect packaging material as some parts are shipped inside Styrofoam packaging. To obtain possible missing parts, refer to the Customer Support section on page 3 of this manual. MC1227 H ANDHELD RODUCT NFORMATION UNIT FEATURES AND 1.
  • Page 7 MC1227 H · The Water Reservoir Cap (1) securely covers the opening to the Water Reservoir, safely containing the pressurized steam within the boiler. The Water Reservoir Cap must be removed in order to fill the unit with water. · The Steam Trigger (2) is depressed in order to release a spray of hot, penetrating steam from the unit.
  • Page 8 Steam Jet Nozzle as illustrated (FIGURE 4). IMPORTANT: To avoid injury, slide utility brush all the way to end of Steam Jet Nozzle as illustrated (FIGURE 4) to ensure no steam escapes. SSEMBLY FIGURE 3 Top Innovations, Inc. NSTRUCTIONS FIGURE 2 FIGURE 4...
  • Page 9 1. Stretch Fabric Steaming Cloth around Utility Attachment Head as shown (FIGURE 8). 2. Slide Utility Attachment Head with attached Fabric Steaming Cloth onto Steam Jet Nozzle. FIGURE 8 SSEMBLY NSTRUCTIONS Top Innovations, Inc. FIGURE 5 FIGURE 6 FIGURE 7...
  • Page 10 FIGURE 12 5. Rotate Steam Jet Nozzle in direction indicated by the “Lock” arrow at rear of nozzle (counter-clockwise). Twist 90 degrees, until properly and securely seated. SSEMBLY FIGURE 10 FIGURE 13 Top Innovations, Inc. NSTRUCTIONS FIGURE 9 FIGURE 11...
  • Page 11 Keep your free hand and any children or pets at a safe distance. 9. Replace Water Reservoir Cap, using caution not to over tighten it. SING THE ANDHELD LEANER Top Innovations, Inc. TEAM...
  • Page 12 Steam Trigger until Steam Ready Light deactivates once again. 5. Once steaming task is complete, immediately unplug power cord from electrical outlet. Follow steps under Proper Storage procedure on page 13 of this manual. SING THE ANDHELD LEANER Top Innovations, Inc. TEAM...
  • Page 13: Proper Storage

    6. Allow to stand for 40 minutes. 7. Drain water-vinegar solution from Water Reservoir. 8. Rinse Water Reservoir with fresh water and drain until vinegar odor dissipates. 9. Replace Water Reservoir Cap. ARE AND TORAGE PROPER STORAGE Top Innovations, Inc. UIDELINES...
  • Page 14: Troubleshooting

    Breaker / Ground Fault Interrupter has tripped or blown a fuse. Mineral buildup in unit. Water Reservoir is empty. Mineral buildup in unit. Top Innovations, Inc. UIDE SOLUTION Plug into electrical outlet. Reset Circuit Breaker / Ground Fault Interrupter, or replace fuse. If you need assistance, contact a qualified electrician.
  • Page 15 THREE MONTH LIMITED WARRANTY (If outside USA, additional shipping charges may apply) Top Innovations, Inc. warrants this product to be free from defects in material and workmanship for a period of three (3) months from the date of purchase. This warranty does not cover damage caused by misuse, negligence, use by...
  • Page 16 Top Innovations, Inc. 400 NW Platte Valley Dr. Riverside, MO 64150 Tel: (800) 711-6617 www.topinnovations.com customerservice@topinnovations.com Printed In China V030918...