Secure Cooktop To Countertop; Electrical Connection - Bosch NIT8053UC Installation Manual

Hide thumbs Also See for NIT8053UC:
Table of Contents

Advertisement

Secure cooktop to
countertop

Electrical connection

NOTE:
8
All manuals and user guides at all-guides.com
The cooktop should be secured to the countertop using the hold down brackets
provided.
Prior to inserting cooktop into cutout, turn cooktop upside down and attach
brackets to the burner box using the washers and screws.
Place cooktop into cutout. Insert clamping screw into the bracket and secure
cooktop to countertop.
Use a wood block to protect fragile countertop materials.
CAUTION: Before installing, turn OFF at the service panel. Lock service panel to
prevent power from being turned ON accidentally.
The branch-circuit breakers ampacity, the wire sizes and the connections must be
conform to the requeriments of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
Frame grounded by connection of grounding lead to neutral lead. If used in a mobile
home or if local codes do not permit grounding through neutral, open connection
and use grounding lead to ground unit in accordance with local codes. Connect
neutral lead to branch-circuit neutral conductor in usual manner.
Attach flexible conduit to the junction box.
CAUTION: To reduce the risk of electric shock and fire, do not use a flexible
power-supply cord.
Connect the cooktop lead wires to the junction box supply wires in proper phase:
black (L1) to black
red (L2) to red
green wire to ground
If the cooktop is installed and connected as specified above, it will be completely
grounded in compliance with the National Electrical Code.

Advertisement

Table of Contents
loading

Table of Contents