Husqvarna 340iBT Workshop Manual page 11

Hide thumbs Also See for 340iBT:
Table of Contents

Advertisement

(CST). The identification number is found on the spare
part.
1. Remove the batteries from the product.
2. Connect the adapter cable (A) to the battery (B) and
to the lower battery slot connector (C) on the
product.
C
3. Start the product.
4. Connect the cable (D) to the common service tool
(CST).
5. Obey the instructions on the common service tool
(CST) and in the related chapter in this manual.
CAUTION: Do not disconnect the product
until the update is completed.
WARNING: Do not push the power trigger.
The motor can start in servicing mode.
4.2.3 To do troubleshooting of the common service
tool
If there is no signal to the common service tool when it is
connected to the product, do the procedure that follows.
1. Make sure that the connectors on the battery and on
the product are clean and not damaged. Replace the
battery or control unit on the product if there is
damage.
2. Make sure that the cable to the common service tool
is clean and not damaged. Replace the cable if there
is damage.
3. Restart the computer.
4. Install the software again.
1126 - 001 - 08.11.2019
A
B
D
Servicing tools - 11

Advertisement

Table of Contents
loading