Chapter 1 Installing Operating System
Between NEC ESMPRO Agent and an https server
Features
Express Report Service (HTTPS)
* In thedirection column, the upper arrow indicates the direction in which the communication started and
the lower arrow indicates the returning communication.
* The port number to be used can be changed from the report setting screen.
* An example of opening the port by using iptables is shown below. Save the setting at the end.
# iptables -I OUTPUT -p tcp --dport 443 -j ACCEPT
# service iptables save
NEC ESMPRO Agent uses the following internal ports. When configuring access control on your server using
iptables or TCP Wrapper, allow these ports as accessible.
Between NEC ESMPRO Agent and another NEC ESMPRO Agent
Feature
rpcbind
NEC ESMPRO Agent
2.3.10

Troubleshooting

If the OS setup does not progress normally, see the following check list.
[?]
RHEL7.2 cannot be installed as described in this manual.
→ Check that the BIOS boot mode is set to UEFI . For details, see Chapter 1 (2.2.3 Checking Boot Mode
Settings).
→ Check that the module POWER lamps of the CPU/IO module 0 and CPU/IO module 1 are lit.
Check that the PRIMARY lamp of the CPU/IO module 0 is lit.
Check that the hard disk drive is mounted only to the slot 0 of the CPU/IO module 0 and CPU/IO module 1,
and the hard disk drive is physically formatted.
For details, see Chapter 1 (2.2.1 Preparation for hardware) in this manual.
[?]
The system suddenly restarts during the setup processing.
→ Check that the BIOS startup monitoring feature is invalid. For details, see Chapter 1 (2.2.2 Disabling OS
Boot Monitoring Feature) in this manual.
[?]
An error or warning message is output during the setup processing.
→ Although an error or warning message may be output due to the temporary system conditions, the setup is
completed successfully if the system FT LED is lit as described on "2.3.6 Installing ft Server Control
Software" in this manual. For the message output after completion of setup, see Chapter 1 (8.3 Problems
When Starting OS) in "Maintenance Guide".
38
ESMPRO/SA
Auto-assign
Port number
111/tcp
111/udp
Auto-assign
Express5800/R320e-E4, R320e-M4 Installation Guide (Linux)
Direction
HTTPS server
443/tcp
2. Setting up
Remarks
https