Connecting The Braking Module - Siemens SINAMIC G130 Operating Instructions Manual

Braking module / braking resistor
Table of Contents

Advertisement

Connection

4.2 Connecting the Braking Module

4.2
Connecting the Braking Module
Interface overview
The Braking Module has the following interfaces:
● DC-link connection via flexible cables or a fixed busbar
● Braking resistor connection via flexible cables or a fixed busbar
● 1 digital input (inhibit Braking Module with high signal/acknowledge error with negative
edge high -> low)
● 1 digital output (Braking Module defective / high signal = no fault)
● PE/protective conductor connection
Connection overview
Figure 4-2
Connection overview for the Braking Module
Note
Common connection for the R1 and DCPA for sizes FX and GX
With Braking Modules for Power Modules of the sizes FX and GX, the interfaces R1 and
DCPA are implemented via a shared connection.
30
Braking Module / braking resistor
Operating Instructions, 11/2017, A5E00331454A