Installation

Electrical connection

Before connecting the appliance, make
sure that the connection data on the
data plate (voltage and frequency)
matches the mains electricity supply.
This data must correspond in order to
avoid the risk of damage to the
appliance. If in any doubt, consult a
qualified electrician.
The necessary connection information
is given on the data plate inside your
appliance.
The fuse rating must be at least 10 A.
The socket must be easily accessible. If
the socket is no longer accessible after
installation, an additional means of
disconnection must be provided for all
poles. Suitable means of disconnection
include switches with an all-pole
contact gap of at least 3 mm. These
include isolator switches, circuit
breakers and relays.
Do not connect the machine to an
inverter. Inverters are used for
autonomous power supply, e.g. a solar
power system. When switched on, peak
loads in the system can cause the
safety switch-off mechanism to be
triggered. This may damage the
electronic unit.
The machine must not be used with so-
called energy saving plugs. These
reduce the amount of energy supplied
to the machine, causing it to overheat.